20
Basic operating modes.
STANDBY mode.
In STANDBY mode, the device is connected to the mains and to the water supply system,
but is in the off state. Water does not run through the device. The LED is off. Voltmeter readings
- 24V, ammeter readings - 0A.
OPERATION Mode.
In the OPERATION mode water is supplied to the device (see Fig. 17,18,19) and the LED
lights up green, indicating that the device has entered a full-fledged OPERATION mode.
If the idle time of the device in the STANDBY mode is more than 8 hours, then when it is
turned on, the green flashing LED lights up for a period of 60 seconds, indicating that stagnant
water must be drained from the system during this time. After 60 seconds the green LED turns
on, indicating that the device has entered the full-fledged OPERATION mode, and the drinking
water quality has returned to normal
.
In OPERATION mode, the voltmeter readings are always around 24V. Ammeter readings
in the OPERATION mode take different values, characterizing the efficiency of the device.
Normal values of the current strength in the OPERATION mode should be in the range of
0.5A -
3.2A
. If the passing current values are below this range, it means either a low TDS of the source
water on which the device operates, or that the device is heavily contaminated and must be flushed
(see the “DEVICE MAINTENANCE” section). If the current values are above this range, it
means that the device operates on water with too high TDS, which can lead to overloading of the
power supply. Overloading of the power supply will occur at passing current strength equal to or
higher than 3.75A. *
Some features of the OPERATION mode.
u
After 480 liters of purified water in the OPERATION mode, when the device is switched
on, the LED will light up orange, indicating that the device SHOULD be flushed with a
lemon acid solution.
u
After 600 liters of purified water in the OPERATION mode, when the device is turned
on, the LED will light up red, indicating that the device MUST be flushed with a lemon
acid solution.
Important!
It is forbidden to continuously use the device in the OPERATION mode for more
than 30 minutes. This may result in malfunction of the control unit. Claims for warranty service in
this case will not be accepted!
If you need to use the device for a longer time, you need to switch the device for 10 minutes to
the STANDBY mode every 30 minutes after the OPERATION mode and then switch the device back
to the OPERATION mode.
*Important!
The ammeter readings in the OPERATION mode should not go beyond the value
of 3.75A. If in the OPERATION mode the current strength is equal to or greater than 3.75A, then the
power supply will be overloaded and the device will be switching off and on for a short time. It is
prohibited to use the device in the overload mode of the power supply (with constant switching on /
off), as this can lead to the device’s failure. In this case, claims for warranty service will not be
accepted!
If this situation occurs regularly, it means that the total mineralization of the source water (TDS)
is too high. In this case, it is necessary to install a water pre-treatment softening system (ion exchange
filters) before the device and/or to purchase a more powerful power source. You can get consultation
concerning this issue by phone 8 (495) 928-77-71 or by email [email protected]