40
24. “BATCH” working mode
BATCH mode.
Signal from an external contact starts the pump to dose the needed quantity set
during program session or for the set number of strokes.
When to use this mode ?
This function allows to begin dosing activities when pump receives an external signal or to
dose in WORK-PAUSE mode.
Which parameters must be set ?
MODE (EXTERNAL - MANUAL - INTERNAL)
ST (strokes)
CC (product’s quantity to dose only if programmed to feed a set amount of chemical)
CC/STROKE (see “setup CC/ST”)
CONTACT (OPEN or CLOSED)
NOTE: Pump must be calibrated (“TEST” function) in order to work properly into this mode. It’s not possible to program the
pump for both modes. Last entry overwrite previous ones.
mode [07]
EXTERNAL
MANUAL
INT: 000’
QUANTITY
ST: 00000
CONTACT:
OPEN
Key
E
Key
E
Key
E
Key
E
Key
E
Key
E
Key
E
QUANTITY
ST: 00000
CONTACT:
CLOSED
QUANTITY
ST: 00000
CONTACT:
DIS.
ST: 1000
MANUAL
Choose working mode:
EXTERNAL:
Pump doses within an amount of time if an external signal is received. External contact can be set as OPEN (normally open) or
CLOSED. (normally closed). Press
“E”
from main mode, choose to dose in ST or CC using
“UP”
key. Set quantity dose and press
“E”
to continue.
Define contact type using
“UP”
key. Press “E” to end procedure.
MANUAL:
Pomp doses at the end of procedure. Press “E” from main mode, choose to dose in ST or CC using “UP” key. Set quantity to dose.
Press “E” to continue, review contact status and press “E”. Pump will begin to dose immediately showing quantity left.
INTERNAL:
This is a “WORK-PAUSE” mode. Dosing will start for set CC or ST quantity and will stop for set time. Press
“E”
from main mode,
choose to dose in ST or CC using
“UP”
key. Set quantity dose and press
“E”
to continue. Define contact type (OPEN or CLOSED) using
“UP”
key. Press “E” to end procedure.