33
MLQ mode.
Dosing rate is determined by pulses from a water meter on the base of set MLQ (milliliters
per quintal), chemical product concentration (%) and quantity for each single stroke set
during program session.
When to use this mode ?
This mode is useful when with an external signal from a pulse sender (as a water meter), it is
necessary to dose the product quantity set specifing the MLQ (milliliters per quintal) and
leaving the pump to manage the coming pulses.
Which parameters must be set ?
MLQ (product quantity in milliliters per quintal)
CONC (% of product’s concentration): set 100% if product is pure
Water Meter Pulses
CC/Stroke
TIMEOUT
BATCH mode.
Signal from an external contact starts the pump to dose product or to produce
an amount of strokes set during program session.
When to use this mode ?
This function allows to begin dosing activities when pump receives an external signal.
Which parameters must be set ?
ST (strokes)
CC (product’s quantity to dose)
VOLT mode.
Voltage from an external device drives the pump that doses proportionally using a minimum
and maximum of strokes for minute set during program session.
When to use this mode ?
This mode is used with controllers provided of a proportional output in voltage.
Which parameters must be set ?
HIV (maximum tension)
LOV (minimum tension)
SPM (strokes per minute)
mA mode.
Current from an external device drives the pump that doses proportionally using a minimum
and maximum of strokes for minute set during program session.
When to use this mode ?
This mode is used with controllers provided of a proportional output in current.
Which parameters must be set ?
HImA (maximum current)
LOmA (minimum current)
SPM (strokes per minute)