18
9. Priming
VMS MF
R: 1.xx
the pump will show the “Delay” (pump’s activation delay) as shown fig.2:
WAITING
00:59
Press any
key to skip the “Delay”. Pump will show “Srokes” (actual strokes) as shown in fig.3:
STROKES
100 SPM
Press and keep pressed the “RIGHT” key to enter into priming mode. Pump will go for 30 seconds into priming mode as shown
in fig.4.
PRIMING
30 Sec.
When the chemical begins to flow out from the outgassing hose then completely close the outgassing knob (except for self-
venting pump heads). This ends the priming procedure. If countdown for priming is not yet ended press
“ESC”
key.
Now the pump is operative. Proceed to setup and programming.
fig.1
fig.2
fig.3
fig.4
PRIMING
To proceed follow these steps: connect all hoses to the pump; open discharge valve by completely turning the discharging knob
(counter clock-wise). Power up the pump.
After pump’s intro (fig.1):