5 MAINTENANCE
5.1 Periodic Maintenance Schedule:
OPERATION
RECOMMENDATION
OUTPUT POWER CALIBRATION
Upon installation and at one-year
intervals thereafter (see section 5.6).
FANS
Inspect every year and clean when
necessary. No lubrication needed.
5.2 Recommended Test Equipment:
EQUIPMENT
MANUFACTURER
MODEL #
Digital Multimeter
HEWLETT PACKARD
E2378A
Oscilloscope
TEKTRONIX
2232
VHF Sweep Generator
WAVETEK
2001
50 Ohm RF Detector
TELONIC BERKELEY
8553
20dB Attenuator
NARDA
766-20
20dB Directional Coupler
NARDA
3001-20
50 Ohm, 500W Dummy Load (2)
BIRD
8833
Power Meter
HEWLETT PACKARD
435B
Frequency Counter
HEWLETT PACKARD
5386A
Spectrum Analyzer
HEWLETT PACKARD
8594E
NTSC Video Generator
Digital Signal Generator
Miscellaneous test cables and
connectors
TEKTRONIX
Agilent
TSG100
E4436B