![EMC VCE VxRail 120 Скачать руководство пользователя страница 73](http://html1.mh-extra.com/html/emc/vce-vxrail-120/vce-vxrail-120_product-manual_2399738073.webp)
Pressing the
ID
button (item 2, Figure 3 and Table 3) on any of the four front control panels will cause the
ID
LED (item 4, Figure 4 and Table 4) on the respective node to blink. This will aid in locating the
appliance with the failed power supply when you are at the rear of the cabinet.
Figure 18: Node controls and indicators
Control panel controls and indicators description
Table 11:
No.
Name
Color
Status
Description
1
Power LED
Blue
On
System power on
Off
Power off
Blue
Blinking
Reports system health fault
2
Node Status LED
Off
Normal - system healthy
Amber
Blinking
Reports system health fault
3
Power button
Press and hold more that four seconds to turn off
node
4
ID LED
Blue
Blinking
Identification activated (from front control panel)
Off
No identification
Replacing a faulted power supply unit
About this task
Disconnect the power supply unit from the power supply source before removing the
power supply unit. Failure to do so could result in damage to the equipment or personal
injury.
Procedure
1
Undo the retaining clip securing the power supply unit AC power cord, and unplug the cord.
2
Pull the power supply unit handle up to the open position.
3
Press the blue latch to the left on the power supply unit.
Replacing hardware