![EMC VCE VxRail 120 Скачать руководство пользователя страница 72](http://html1.mh-extra.com/html/emc/vce-vxrail-120/vce-vxrail-120_product-manual_2399738072.webp)
power supply unit (PSU1 or PSU2) will cause the
Power
button with
Status
LED (item 1, Figure 3 and
Table 3) on all four control panels to blink amber and blue.
Figure 17: Node control panel controls and indicators
Control panel controls and indicators description
Table 10:
No.
Name
Color
Status
Description
1
Power button with
Status LED
Blue
On
System power on
Off
System power off
Amber
Blinking
DC off and fault
Amber and
Blue
Blinking
DC on and fault
2
ID button with LED Blue
Blinking
Identification activated
Off
No identification
Each node is equipped with a power button and three LED indicators, which are visible at the rear of the
appliance. A fault with either power supply unit (PSU1 or PSU2) causes the
Power
LED (item 1, Figure 4
and Table 4) to blink blue, and the
Node Status
LED (item 2, Figure 4 and Table 4) to blink amber on all
four nodes.
VCE VxRail
™
Appliance 3.5 Product Guide
Replacing hardware
72
©
2016 VCE Company, LLC.
All Rights Reserved.