No.
Description
1
Ionizer
2
Electrode cartridge
3
One-touch fitting
4
End bracket
5
Center bracket
6
Feedback sensor
7
Autobalance sensor
8
Power supply cable
Specifications
Ionizer model
Ion generation method
Method of applying voltage
Output for emitting electricity
Ion balance
Note 1)
Air purge
Fluid
Operating pressure
Connecting tubing O.D.
Power supply voltage
Current
consumption
Sensing DC mode
Pulse DC mode
DC mode
Input signal
Emission of static electricity is suspended.
Maintenance
Output signal
Static electricity removal is completed.
Max. load
Residual
Max. applied
Maintenance output
Irregularity
Sensor monitor output
Note 2)
Effective discharge distance
Operating ambient temperature, Operating fluid temperature
Operating ambient humidity
Material
Vibration resistance
Shock resistance
Compliance with overseas standards / directives
Note 1) For the case where air purge is performed between a charged
Note 2) For cases where the potential of a charged object is measured
voltage and the detection range of the sensor will vary depending
Number of Electrode Cartridges and Weight
Bar length (mm)
300
Number of electrode cartridges
3
Weight (g)
470
Sensor
Sensor model
Operating ambient temperature
Operating ambient humidity
Case material
Vibration resistance
Shock resistance
Weight
Installation distance
Compliance with overseas standards / directive
Construction
Ionizer
Series
IZS31-
(NPN specification)
IZS31-
P
Corona discharge type
Sensing DC, Pulse DC, DC
±
7000 V
±
30 V (Stainless electrode needle:
±
100 V)
Air (Clean and dry)
0.7 MPa or less
ø
4
24 VDC
±
10%
200 mA or less (While standing by: 120 mA or less)
200 mA or less (When sensor is not used: 170 mA or less)
170 mA or less
Contact input signal with no voltage
load current: 100 mA
Residual voltage: 1 V or less (At load current 100 mA)
applied voltage: 28 VDC
Max. load current: 100 mA
Residual voltage: 1 V or
Voltage output 1 to 5 V (Connect a 10 k
Ω
or larger load.)
50 to 2000 mm (Sensing DC mode: 200 to 2000 mm)
0 to 50
°
C
35 to 80%Rh (With no condensation)
Cover of ionizer: ABS, Electrode needle: Tungsten, Monocrystal silicon,
Durability 50 Hz Amplitude 1 mm XYZ each 2 hours
10 G
CE (EMC directive: 89/336/EEC, 92/31/EEC, 93/68/EEC, 2004/108/EC,
Low voltage directive: 73/23/EEC, 93/68/EEC)
charged object and an ionizer at a distance of 300 mm.
measured using a feedback sensor, the relationship between the potential being measured,
depending on the sensor’s installation distance. Refer to page 3.
Weight
380
620
780
1100
1260
1500
4
7
9
13
15
18
530
720
850
1100
1220
1410
IZS31-DF
(Feedback sensor)
IZS31
(Autobalance
0 to 50
°
C
35 to 80%Rh (With no condensation)
ABS
ABS, Stainless
Durability 50 Hz Amplitude 1 mm XYZ each 2 hours
10 G
200 g (Including cable weight)
220 g (Including
10 to 50 mm (Recommended)
CE (EMC directive: 89/336/EEC, 92/31/EEC, 93/68/EEC, 2004/108/EC,
Low voltage directive: 73/23/EEC, 93/68/EEC)
r
t q
i
e
y
w
u
Series
IZS31
(
PNP specification)
less)
mA
or less (At load current 100 mA)
load.)
mm)
silicon, Stainless steel
hours
2004/108/EC,
measured, the sensor monitor output
1900
2300
23
28
1730
2040
IZS31-DG
(Autobalance sensor)
Stainless steel
hours
(Including cable weight)
—
2004/108/EC,
i