12
Serial/Ethernet/USB Communication (SCOM) Interface
IND100084-18
CMD
Message Commands and Queries (CMD) Contents
The command can be one of the following values and consists always of 3 bytes in positions 2,3,4:
Byte 2 Byte 3 Byte 4 ASCII
Description
I/O
Non-Volatile / Volatile Page
0x42
0x52
0x49
BRI
Minimum Brightness
R/W
NV
15
0x42
0x52
0x4D
BRM
Maximum Brightness
R/W
NV
16
0x42
0x52
0x54
BRT
Brightness Control
R/W
V
17
0x42
0x52
0x4C
BRL
GDC LED Brightness Control
R/W
NV
18
0x42
0x52
0x55
BRU
User Brightness Control
R/W
NV
19
0x47
0x4D
0x42
GMB
GDC minimum brightness
R/W
NV
20
0x47
0x42
0x46
GBF
Keypad Brightness auto follow
R/W
NV
21
0x4C
0x49
0x53
LIS
Read Ambient Light Sensor
R
24
0x4F
0x44
0x4D
ODM
Outdoor Mode
R/W
NV
25
0x52
0x45
0x43
REC
Recall GDC
W
26
0x50
0x4F
0x54
POT
Potential Meter Control
R/W
NV
27
0x42
0x5A
0x5A
BZZ
Buzzer Control On/OFF
R/W
V
28
0x53
0x57
0x49
SWI
Read NXP Firmware Version
R
30
0x53
0x57
0x56
SWV
Read Video Scaler Firmware Version
R
30
0x54
0x59
0x50
TYP
Read Type Number
R
31
0x53
0x4E
0x42
SNB
Read Serial Number
R
31
0x53
0x43
0x49
SCI
Write Customer Service ID
W
NV
32
0x43
0x53
0x49
CSI
Read Customer Service ID
R
32
0x45
0x54
0x43
ETC
Elapsed Time Counter Query System
R
32
0x4D
0x41
0x4E
MAN
Read Manufacture ID Code
R
33
0x54
0x4D
0x50
TMP
Read Temperature Sensor
R
33
0x56
0x45
0x52
VER
Inquiry specific Type Number
R
34
0x46
0x57
0x56
FWV
Inquiry Firmware Versions
R
34
0x43
0x42
0x52
CBR
COM1&2 Port Baudrate
R/W
NV
35
0x42
0x41
0x4B
BAK
Turn on/off acknowledge on broadcast command
R/W
NV
36
0x44
0x4C
0x4E
DLN
Download ECDIS Package
R
37
0x44
0x4C
0x3F
DL?
Request Number of available ECDIS Pack
R
38
0x43
0x41
0x4C
CAL
ECDIS calibrated brightness inquiry
R
39
0x52
0x43
0x46
RCF
Recall Factory default
W
40
0x50
0x57
0x52
PWR
Power On/Off/Sleep unit
W
41
0x56
0x55
0x52
VUR
Read User Configuration from Video Scaler
R
42
0x56
0x55
0x53
VUS
Write User Configuration to Video Scaler
W
43
0x07
0xFF
0x4D
MOD
Operation Mode Selection
R/W
44
0x4D
0x43
0x43
MCC
OSD Menu Control Co Commands List Table*
R/W
45-54
I/O
=
R=Read, W=Write.
Volatile
=
V=The variable values controlled by these commands are cleared at power restart).
Non-Volatile =
NV=The variable values controlled by these commands are stored even after power restart.
Page #
=
Page number in this manual where command is detailed.
*
MCC
OSD Menu Control Commands. "MCC" command also features a Query "?" mode, "R" or "r" reset mode to factory default,
in1 from current value "+" and decrease -1 from current value "-". Details and usage of these commands are available
later in this manual.
Содержание HATTELAND TECHNOLOGY X MMD G2 Series
Страница 56: ...56 This page left intentionally blank...
Страница 57: ...57 Appendixes...
Страница 68: ...Hatteland Technology AS www hattelandtechnology com Enterprise no NO974533146...