34
Serial/Ethernet/USB Communication (SCOM) Interface
IND100084-18
"VER" - Read Specific Type
This command is used to read the specific Type segment in Type Number. The returned value is the three characters
from pos 8 to 10 in stored Type Number. If there is no type number stored, return 0 byte.
For example, if the type number is "HD55T22MVDMA1AAAAAAA", VER should return "MVD"
The purpose of defining this command is to be compatible with old SCOM command.
Example:
Read "Ver":
0x07
0xFF
0x56
0x45
0x52
0x00
0x0C
ACK Reply from unit:
0x06
0xFF
0x56
0x45
0x52
0x03
0x0A
0x4A
0x48
0x44
0x29
"FWV" - Read Firmware information
This command will be used to read various firmware versions.
The purpose of defining this command is to be compatible with old SCOM command.
Byte #
0
1
2
3
4
5
6
7
8
0x07 0xFF 0x46 0x57 0x56 0x01 IHCHK FW Type IDCHK
FW TYPE:
Specify the firmware type.
Range: Valid values in table
Device Type
Value
Comment
Microcontroller Firmware
0x00
Same as SWI
Video Scaler
0x01
Same as SWV
Microcontroller Config File
0x02
Example:
Get Microcontroller Firmware :
0x07
0xFF
0x46
0x57
0x56
0x01
0x19
0x00
0xFF
ACK reply from unit: "00004"
0x06
0xFF
0x46
0x57
0x56
0x05
0x19
0x30
0x30
0x30
0x30
0x34
0x0B