background image

P3    OVERVIEW

1. OVERVIEW

ICF  series  cartridge  filter  combines  superior  water  filtration  with  ease  of  operation  and  corrosion-free 

construction. With filtration ratings of 6,000~7,200 gallons (22,710 ~ 27,250 liters) per hour, they are designed 

for  continuous  or  intermittent  operation,  for  installation  above  or  below  the  pool  waterline,  for  fresh  or 

saltwater  swimming  pools  or  spas.  ICF  series  filters  utilize  multiple  reusable,  reinforced  polyester  filter 

cartridge elements to provide a high degree of water clarity and long filter cycles with minimum care.

READ UNDERSTAND AND FOLLOW ALL SAFETY AND OPERATION:

Do  not  operate  the  filter  until  you  have  read  and  understand  clearly  all  the  operating 

instructions  and  warning  messages  for  all  equipment  that  is  a  part  of  the  pool  circulating 

system. The following instructions are intended as a guide for initially operating the filter in 

a  general  pool  installation.  Failure  to  follow  all  operating  instructions  and  warning 

messages can result in property damage or severe personal injur y or death.

To reduce the risk of injur y, do not permit children to use this product.

ELECTROCUTION HAZARD

Direct water discharge from air relief valve away from electrical ser vice. Do not locate pump

 

control over near the filter.

Due to the potential risk that can be involved, it is recommended that the 

pressure test be kept to the minimum time required by the local code. Do 

not allow people to work around the system when the circulation system 

is under the pressure test. Post appropriate warning signs and establish a 

barrier around the pressurized equipment. If the equipment is located in 

an equipment room, lock the door and post a warning sign.

Never  attempt  to  adjust  any  closures  or  lids  or  attempt  to  remove  or  tighten  bolts  when  the  system  is 

pressurized. These actions can cause the closure to separate and could cause severe personal injur y or death if 

they were to strike a person.

N e v e r  e x c e e d  t h e  m a x i m u m  o p e r a t i n g  p r e s s u r e  o f  s y s t e m 

components.  Exceeding  these  limits  could  result  in  a  component 

failing under pressure. This instantaneous release of energy can cause 

the  closure  to  separate  and  could  cause  severe  personal  injur y  or 

death if they were to strike a person.

HYPERTHERMIA

 

SPA  water  temperature  excess  of  38°C  (104°F)  may  be  injurious  to 

health. 

  Measure  water  temperature  before  entering  SPA  to  strike  a 

person.

Hyperthermia occurs when the internal temperature of the body reaches a level several degrees above the 
normal body temperature of 98.6 °F (37 °C). The symptoms of hyperthermia include drowsiness, lethargy, and 
an increase in the internal temperature of the body.

Содержание 9140401

Страница 1: ...USER MANUAL SINGLE ELEMENT CARTRIDGE FILTER Installation and Operation Models ICF100 ICF150 ICF200 EMFI22050602...

Страница 2: ...TER SYSTEM 3 3 OPERATION 4 MAINTAINING YOUR FILTER 4 2 REMOVING CARTRIDGE 4 3 CLEANING CARTRIDGE 4 4 FILTER REASSEMBLY INSTRUCTION 4 4 1 RE INSTALLING CARTRIDGE 4 4 2 CLEAN SEAL RING AND SEAL SURFACE...

Страница 3: ...g your dealer or a qualified pool technician 2 Read the entire Installation Operation Manual before attempting to use service or adjust the pool filtering system 2 Before repositioning valve s and bef...

Страница 4: ...o not locate pump control over near the filter Due to the potential risk that can be involved it is recommended that the pressure test be kept to the minimum time required by the local code Do not all...

Страница 5: ...e shade to shield it from direct sunlight 5 Connect the pool suction plumbing between the skimmer the pool outlet from the pool and the pump 6 Install the plumbing from the filter to the pool return t...

Страница 6: ...n all system valves to allow water from the pool to the filtration system and from the filter to return to the pool 4 Place the air relief valve in an OPEN position Figure 3 Air relief valve in an ope...

Страница 7: ...rate of the system 3 3 OPERATION Figure 4 1 Turn off all system circulation pumps and all electrical power on the equipment pad 2 Set all system valves in a position to prevent water from flowing to...

Страница 8: ...EMAUX lock ring system only tighten the lock ring clockwise until the latch is locked on position 3 Ensure that upper and bottom bodies are properly secured with the lock ring NOTE DO NOT HIT OR STRIK...

Страница 9: ...LATION OF THE AIR RELIEF VALVE In areas where sub freezing temperatures can be expected the filter should be drained to protect the filter from damage 1 Follow the steps in Filter disassemble instruct...

Страница 10: ...g D306Xd7 5 1 7 430178159 Union nut 2 2 8 430308158 Union 2inch 2 5inch ANSI 2 9 111040071 O ring D77Xd62X8 2 10 E140401 ICF100 200 Bottom Body 1 11 E160553 End cap with O ring 1 12 E010201 Air Relief...

Страница 11: ...perior to new parts in performance This Limited Warranty extends only to products purchased from Emaux authorized reseller Does not extend to any product that has been damaged or rendered defective a...

Страница 12: ...YOUR PREMIER SUPPLIER www emauxgroup com EMAUX WATER TECHNOLOGY CO LTD...

Отзывы: