background image

IN

CM

IN

CM

IN

CM

ICF100

ICF150

ICF200

Model

IN

CM

A

B

C

D

20.9

53.05

9.05

23

.

00

18

.

30

46

.

40

3

.

20

8

.

20

20.9

53.05

12

.

40

31

.

50

18

.

30

46

.

40

3

.

20

8

.

20

20.9

53.05

17

.

24

43

.

80

18

.

30

46

.

40

3

.

20

8

.

20

INSTALLATION     P4

This product should be installed and ser viced only by qualified pool professional.   

1. The filter system should be installed on a level concrete slab or another rigid base. Select a well-drained and 

vented area, that does not flood when it rains. Position the filter so that the piping connections and winter 

drain are convenient and accessible for operation, ser vice, maintenance, and winterizing. 

2. Position filter body such that all operation and safety labels are visible.

3. Position the filter so the filter will drain by gravity.

4. If practical, place the pump and filter in the shade to shield it from direct sunlight.

5. Connect the pool suction plumbing between the skimmer, the pool outlet (from the pool), and the pump.

6. Install the plumbing from the filter to the pool (return to the pool)

7. Do not locate pump controls over or near the filter.

8. Verify water discharge from the manual air Relief valve is directed away 

from electrical devices.

2. INSTALLATION

1.1 PRODUCT INFORMATION

1.2 DIMENSIONS

A

B

D

C

Model

EFFECTIVE FITRATION

AREA

ICF100

ICF150

ICF200

CODE

DESIGN FLOW RATE

Residential        Commercial

100

 150

200

FT²

9.29

13.94

18.58

100

 120

120

GPM

379

455

455

LPM

9140401

9140402

9140403

[ Filter rate for residential use based on 1GPM/ft². Recommend Flow Rate for 2” piping is 90

x  150 GPM ]

 

≤  ≤

A

REQUIRED CLEARANCE

“B” side

“C” above 

IN

32.6

36

40.7

CM

82.7

91.2

103.4

IN

18.3

18.3

18.3

CM

46.4

46.4

46.4

IN

11.8

11.8

11.8

CM

30

30

30

ICF 100

ICF 150

ICF 200

MODEL

Drain plug

Outlet

Bottom body

Inlet

Lock Ring

Upper body

Air relief valve

Pressure gauge

Latch

A

C

B

Содержание 9140401

Страница 1: ...USER MANUAL SINGLE ELEMENT CARTRIDGE FILTER Installation and Operation Models ICF100 ICF150 ICF200 EMFI22050602...

Страница 2: ...TER SYSTEM 3 3 OPERATION 4 MAINTAINING YOUR FILTER 4 2 REMOVING CARTRIDGE 4 3 CLEANING CARTRIDGE 4 4 FILTER REASSEMBLY INSTRUCTION 4 4 1 RE INSTALLING CARTRIDGE 4 4 2 CLEAN SEAL RING AND SEAL SURFACE...

Страница 3: ...g your dealer or a qualified pool technician 2 Read the entire Installation Operation Manual before attempting to use service or adjust the pool filtering system 2 Before repositioning valve s and bef...

Страница 4: ...o not locate pump control over near the filter Due to the potential risk that can be involved it is recommended that the pressure test be kept to the minimum time required by the local code Do not all...

Страница 5: ...e shade to shield it from direct sunlight 5 Connect the pool suction plumbing between the skimmer the pool outlet from the pool and the pump 6 Install the plumbing from the filter to the pool return t...

Страница 6: ...n all system valves to allow water from the pool to the filtration system and from the filter to return to the pool 4 Place the air relief valve in an OPEN position Figure 3 Air relief valve in an ope...

Страница 7: ...rate of the system 3 3 OPERATION Figure 4 1 Turn off all system circulation pumps and all electrical power on the equipment pad 2 Set all system valves in a position to prevent water from flowing to...

Страница 8: ...EMAUX lock ring system only tighten the lock ring clockwise until the latch is locked on position 3 Ensure that upper and bottom bodies are properly secured with the lock ring NOTE DO NOT HIT OR STRIK...

Страница 9: ...LATION OF THE AIR RELIEF VALVE In areas where sub freezing temperatures can be expected the filter should be drained to protect the filter from damage 1 Follow the steps in Filter disassemble instruct...

Страница 10: ...g D306Xd7 5 1 7 430178159 Union nut 2 2 8 430308158 Union 2inch 2 5inch ANSI 2 9 111040071 O ring D77Xd62X8 2 10 E140401 ICF100 200 Bottom Body 1 11 E160553 End cap with O ring 1 12 E010201 Air Relief...

Страница 11: ...perior to new parts in performance This Limited Warranty extends only to products purchased from Emaux authorized reseller Does not extend to any product that has been damaged or rendered defective a...

Страница 12: ...YOUR PREMIER SUPPLIER www emauxgroup com EMAUX WATER TECHNOLOGY CO LTD...