ICF100
ICF150
ICF200
Model
IN
CM
A
B
C
D
20.9
53.05
9.05
23
.
00
18
.
30
46
.
40
3
.
20
8
.
20
20.9
53.05
12
.
40
31
.
50
18
.
30
46
.
40
3
.
20
8
.
20
20.9
53.05
17
.
24
43
.
80
18
.
30
46
.
40
3
.
20
8
.
20
INSTALLATION P4
This product should be installed and ser viced only by qualified pool professional.
1. The filter system should be installed on a level concrete slab or another rigid base. Select a well-drained and
vented area, that does not flood when it rains. Position the filter so that the piping connections and winter
drain are convenient and accessible for operation, ser vice, maintenance, and winterizing.
2. Position filter body such that all operation and safety labels are visible.
3. Position the filter so the filter will drain by gravity.
4. If practical, place the pump and filter in the shade to shield it from direct sunlight.
5. Connect the pool suction plumbing between the skimmer, the pool outlet (from the pool), and the pump.
6. Install the plumbing from the filter to the pool (return to the pool)
7. Do not locate pump controls over or near the filter.
8. Verify water discharge from the manual air Relief valve is directed away
from electrical devices.
2. INSTALLATION
1.1 PRODUCT INFORMATION
1.2 DIMENSIONS
A
B
D
C
Model
EFFECTIVE FITRATION
AREA
ICF100
ICF150
ICF200
CODE
DESIGN FLOW RATE
Residential Commercial
100
150
200
FT²
9.29
13.94
18.58
M²
100
120
120
GPM
379
455
455
LPM
9140401
9140402
9140403
[ Filter rate for residential use based on 1GPM/ft². Recommend Flow Rate for 2” piping is 90
x 150 GPM ]
≤ ≤
A
REQUIRED CLEARANCE
“B” side
“C” above
IN
32.6
36
40.7
CM
82.7
91.2
103.4
IN
18.3
18.3
18.3
CM
46.4
46.4
46.4
IN
11.8
11.8
11.8
CM
30
30
30
ICF 100
ICF 150
ICF 200
MODEL
Drain plug
Outlet
Bottom body
Inlet
Lock Ring
Upper body
Air relief valve
Pressure gauge
Latch
A
C
B