EM TEST
PFS 200 Series
Manual for Operation
V 3.08
28 / 34
6.2.
Trigger
Automatic
automatic release of the events
- Repetition rate
0.1 s
– 999 s
0.10 s
–
1.00 s
step 0.01 s
1.00 s
–
10.00 s
step 0.1 s
10.00 s
– 999.00 s
step 1.0 s
- Drop out duration td
– Dip duration
1.0
s - 9999ms
0.001ms
– 1.00 ms
step 0.001 ms
1.00ms
– 10.00 ms
step 0.01 ms
10.0ms
– 9999 ms
step 0.1 ms
Manual
single event trigger
External
trigger by external signal
6.3.
Measurement
BNC connector CRO I
internal current sensor for nominal current, inrush current
10mV / A max. 700A
BNC connector CRO TRIGGER
trigger for oscilloscope positive ramp to +15V
delay approx. 30ms
6.4.
Test routines
Quick Start
All parameters adjustable while test is running
Standard test Routines
1. Chrysler PF 9326
2. Ford
3. PSA / Renault
Service
Addresses
Selftest
Set-up
6.5.
Interfaces
Serial Interface USB
Setting Baudrate (RS232: 9'600 , 19'200 Baud )
Parallel Interface IEEE
Addresses 1
– 30
Analogue output
0
– 10V DC to control external voltage sources
6.6.
General
Device
PFS 200N30,N50,N100
PFS 200N150, N200
Dimensions
19” / 3 HU
19” / 6 HU
Weight
N30 / N50: 10.8 kg N100: 14kg
approx. 30 kg
Power supply
115/230V +10/-15% 50/60Hz (optional 115 V)
Max. 60 VA
Fuses
2 * 1 A T
6.7.
Environmental conditions
Temperature
10 °C to 35 °C
Hunidity
30 % to 70 %; non condensing
Atmospheric pressure
86 kPa (860 mbar) to 106 kPa (1 060 mbar)
=> Not relevant data for the standards can be changed by the manufacturer <=