EM TEST
CNI 501 / CNI 503
Manual of operation
V 3.32
28 / 41
9.
Special coupling networks
9.1.
CNI 501B9
9.1.1. Operating elements
Figure 9.1: CNI 501B9 font view
1
"TEST ON
2
Switching ANSI -IEC
3
LED display Pulse (EFT / 50
HFK / Surge)
4
LED display couplings
5
Switch AC / DC mode
6
EFT output to HFK coupling clamp
7
EFT input from UCS 500Mx
8
EUT Output L1/DC+, L2, L3, N/DC-, PE
9
Earth plug for EFT burst verification
10
COM output for ext. surge coupling networks
11
HV output for ext. surge coupling networks
Figure 9.2: Rear side CNI 501 B9
1
EUT power L
2
EUT power N
3
EUT power PE
4
Ground Reference
5
DC+ Input from power supply
6
DC- Input from power supply
7
Surge COM Input from generator
8
Surge HV Input from generator
9
Power switch with fuse
10
CN control input from UCS generator