4.
Technical Data CNI 503
4.1.
EUT power supply
Pulse peak
Coupling network
EUT supply 50/60Hz
Remarks
voltage
IEC, ANSI,
Ringwave
IEC
Voltage
Current ac/dc
ac dc
5.5kV
CNI 501
1x250V
32A dc 48V/32A
CNI 501 S1
1x250V
100A dc 75V/100A
5.5kV
CNI 503 A
3x480V
16A
CNI 503 A2
3x480V
32A
CNI 503 A2
3x480V
32A dc 1000V 32A
CNI 503 A3
3x480V
63A
requires MRAC or RAC
CNI 503 A4
3x480V
100A
requires MRAC or RAC
CNI 503 A5 S22 3x480V
200A
requires MRAC or RAC
CNI 503 A2.10
3x690V, 1000V
32A
No Test ON
CNI 503 A S1
3x690V
16A
CNI 503 A S2
3x690V
32A
CNI 503 A S3
3x690V
63A
requires MRAC or RAC
CNI 503 A S4
3x690V
100A
requires MRAC or RAC
7kV
CNI 503 B5
CNI 503 A5
3x480V
16A
CNI 503 B7
CNI 503 A7
3x480V
32A
CNI 503 B7.2
3x480V, 1000V
32A
No Test ON
CNI 503 B7.3
3x480V, 1000V
32A
Test ON, need MRAC or RAC
CNI 503 B7.4
3x690V, 1000V
32A
No Test ON, need MRAC or RAC
CNI 503 B8
CNI 503 A8
3x480V
63A
requires MRAC or RAC
CNI 501 B9
250V, 75V
100A
6 HU,
Test ON
CNI 503 B9
CNI 503 A9
3x480V
100A
requires MRAC or RAC
CNI 503 B9.2
3x480V, 1000V
100A
No Test ON, need MRAC or RAC
CNI 503 B9.6
3x480V, 1000V
100A
Test ON, need MRAC or RAC
CNI 503 B S1
3x690V
16A
CNI 503 B S2
3x690V
32A
CNI 503 B S3
3x690V
63A
requires MRAC or RAC
CNI 503 B S4
3x690V
100A
requires MRAC or RAC
8kV
CNI 503 A10
3x480V
16A
CNI 503 A12
3x480V
32A
CNI 503 A13
3x480V
63A
requires MRAC or RAC
CNI 503 A14
3x480V
100A
requires MRAC or RAC
CNI 503 A14.1
3x480V
100A
requires MRAC or RAC
10kV
CNI 501 S4
1x250V
10A
CNI 501 S6
1x250V
16A Generator impedance
2
Ω
CNI 503 A16
3x480V
16A
CNI 503 A18
3x480V
32A
CNI 503 A19
3x480V
63A
requires MRAC or RAC
CNI 503 A20
3x480V
100A
requires MRAC or RAC
CNI 503 A16 S1 3x690V
16A