16
6900
EN
Programming intercommunicating call buttons
To program the buttons, proceed as follows:
1) Press “speak/listen” or lift the handset (depending on the
model installed)
of the interphone you wish TO CALL.
2) Press and hold button
B
on the
interphone you wish to
program (making the call)
.
3) Press and hold button
A
at the same time.
4) Wait for the RED LED to flash.
5) Release buttons
A
and
B
.
6) Press and hold the button you wish to program (e.g.
E1
,
E2
,
E3
,
E4
,
E5
,
E6
).
7) Wait for the interphone to emit a chime.
8) Release the button you wish to program on the
interphone
making the call
.
9) Press a button (lock/F1/F2)
on the interphone you wish
to call
.
10)
A “note” on the interphone (making the call) being pro-
grammed confirms the setting has been saved.
Important:
This procedure can be used to manually repro-
gram the buttons, with the exception of the speak/listen button
(not programmable) and the lock and self-start buttons (for
which programmer 950C or SaveProg software is required).
Programming the self-activation/self-start button
to a specific panel
(different from the self-start function enabled using button
“A”)
1) Press and hold button
B
.
2) Press and hold button
A
at the same time.
3) Wait for the RED LED to flash.
4) Release buttons
A
and
B
.
5) Press and hold the button you wish to program (excluding
speak/listen, lock and self-start).
6) Wait for the interphone to emit a tone.
7) Release the button.
8) For entrance panels with buttons, press the button corre
-
sponding to the monitor on which the button is being saved.
For alphanumeric entrance panels, enter the ID number
corresponding to the monitor on which the button is being
saved, and confirm using the bell button on the entrance
panel.
9) At the end of the procedure described above, a sharp tone
will be emitted by the interphone, while the entrance panel
makes a call to the interphone on which programming has
taken place.
Reprogramming the default value separately for
each button
1) Press and hold button
B
.
2) Press and hold button
A
at the same time.
3) Wait for the red LED to flash.
4) Release buttons
A
and
B
.
5) Press and hold the button for which you wish to restore
the default setting (does not apply to Self-start and Lock
buttons).
6) Wait for the interphone to emit a tone.
7) Release the button.
8) Press the button again (it will now be restored to its default
value).
Table of primary and respective secondary ID codes:
Primary
ID
Secondary ID
1
2
3
1
51
52
53
2
54
55
56
3
57
58
59
4
60
61
62
5
63
64
65
6
66
67
68
7
69
70
71
8
72
73
74
9
75
76
77
10
78
79
80
11
81
82
83
12
84
85
86
13
87
88
89
14
90
91
92
15
93
94
95
16
96
97
98
17
99
100 101
18
102 103 104
19
105 106 107
20
108
109 110
21
111 112 113
22
114 115 116
23
117
118
119
24
120 121 122
25
123 124 125
Primary
ID
Secondary ID
1
2
3
26
126
127
128
27
129
130
131
28
132
133
134
29
135
136
137
30
138
139
140
31
141
142
143
32
144
145
146
33
147
148
149
34
150
151
152
35
153
154
155
36
156
157
158
37
159
160
161
38
162
163
164
39
165
166
167
40
168
169
170
41
171
172
173
42
174
175
176
43
177
178
179
44
180
181
182
45
183
184
185
46
186
187
188
47
189
190
191
48
192
193
194
49
195
196
197
50
198
199
200
Important:
Delete from Group: to delete from a group, the
programming deletion procedure described in the “Deleting
programming” section must be carried out (all programming
deleted).
Button programming
Important
:
without programmer 950C or SaveProg software,
the only functions that can be assigned are intercommunica-
ting, specific entrance panel self-activation, restoring buttons
programmed by the installer to their default settings and dele-
ting all programming procedures performed.
A
B
C
E2 E3
E1
E5 E6
E4
D