13
6900
EN
2) Press and hold buttons
E3
and
E4
simultaneously, until the
red LED begins to flash.
3) While both LEDs are flashing, press button
B
(speak/listen)
to confirm the change.
The red LED switches off as soon as button
B
is pressed,
while the green LED flashes for a few seconds when it swi
-
tches off, the interphone emits a tone.
Important
: This procedure applies for both enabling and di-
sabling, once to enable and another time to disable.
A
B
E3 E4
Selecting call melodies
Melodies can be selected and adjusted. Different melodies
can also be set for outdoor, intercommunicating and door calls
(see below). Melodies are adjusted while the interphone is in
standby.
Button
A
is used to enter programming mode.
Button
E1
selects the ENTRANCE PANEL CALL melody.
Button
E2
selects the INTERCOMMUNICATING CALL me-
lody.
Button
E3
selects the AUDIO DOOR CALL melody (using only
landing call button 20577 or 14577 by Vimar).
A
B
E2 E3
E1
Configuration:
1) Press and hold button
A
until the green LED begins to flash;
this will also be confirmed by a beep.
2) Press and hold the button corresponding to the desired
chime (button
E1
/button
E2
/button
E3
) until you hear the
melody on the interphone.
3) Press the button (button
E1
/button
E2
/button
E3
) repeate-
dly to select the desired melody.
4) Once you have selected the desired chime, press button
A
to store it or do not touch any buttons for 5 s. Once configu
-
ration is complete, the flashing green LED switches off.
Chime volume adjustment
Button
A
is used to enter adjustment mode.
Button
E5
decreases the melody volume.
Button
E6
increases the melody volume.
A
E5 E6
Configuration:
1) Press and hold button
A
until the green LED begins to flash;
this will be confirmed by a beep.
2) Press button
E5
or
E6
depending on the procedure you
want to carry out (decrease or increase the chime volume).
3) Once you have selected the desired volume, press button
A
to store it or do not touch any buttons for 5 s. Once con-
figuration is complete, the flashing green LED switches off
and a beep is emitted.
Muting the chime (User away function)
Using the same procedure as described above for volume
adjustment, press button
E5
several times to reach the point
at which the chime is deactivated. “Chime muted” status is
indicated by the red LED lighting up steadily.
If the interphone receives a call from the entrance panel while
the chime is muted, the red LED indicates this with one flash
for each unanswered call, for a maximum of 4 calls (these fla
-
shes occur every 10 s). When the chime volume is restored, at
least to its minimum level, this indication will be reset.
Adjusting the conversation volume (from entrance
panel to interphone)
The volume is adjusted during conversation.
Button
A
is used to enter adjustment mode.
Button
E5
decreases the conversation volume.
Button
E6
increases the conversation volume.
Configuration:
1) Press and hold button
A
until the green LED begins to flash
(both LEDs are lit).
2) Press button
E5
or
E6
depending on the procedure you
want to carry out (decrease or increase the conversation
volume).
3) Once you have selected the desired volume, press button
A
to store it or do not touch any buttons for 5 s. Once con-
figuration is complete, the flashing green LED switches off
and a beep is emitted.