 5. Troubleshooting  

 

Following are a few common problems that may occur during operation. Here are 

some suggestions for easy troubleshooting: 

 

A. The unit does not work, no light and the fan does not work 

1.  Check the connection of power and main fuse. 

2.  Measure the mains voltage on the main connector. 

3.  Check the power on LED. 

B. Not responding to DMX controller 

1.  DMX LED should be on. If not, check DMX connectors, cables to see if link properly. 

2.  If the DMX LED is on and no response to the channel, check the address settings and           

DMX polarity. 

3.  If you have intermittent DMX signal problems, check the pins on connectors or on PCB 

of the unit or the previous one. 

4.  Try to use another DMX controller.     

5.  Check if the DMX cables run near or run alongside to high voltage cables that may 

cause damage or interference to DMX interface circuit.   

C. Some units don’t respond to the easy controller   

1.  You may have a break in the DMX cabling. Check the LED for the response of the 

master/ slave mode signal. 

2.  Wrong DMX address in the unit. Set the proper address. 

D. No response to the sound 

1.  Make sure the unit does not receive DMX signal. 

2.  Check microphone to see if it is good by tapping the microphone 

E. One of the channels is not working well 

1.  The stepper motor might be damaged or the cable connected to the PCB is broken. 

2.  The motor’s drive IC on the PCB might be out of condition 

 

 

 

 

 

2-

  1. Safety Instruction 

 

 

 

WARNING

 

y

  Please keep this User Guide for future consultation. If you sell the unit to another user, be 

sure that they also receive this instruction booklet. 

y

  Unpack and check carefully there is no transportation damage before using the unit. 

y

  Before operating, ensure that the voltage and frequency of power supply match the power 

requirements of the unit.   

y

 It’s important to ground the yellow/green conductor to earth in order to avoid electric 

shock. 

y

  The unit is for indoor use only. Use only in a dry location. 

y

 The unit must be installed in a location with adequate ventilation, at least 50cm from 

adjacent surfaces. Be sure that no ventilation slots are blocked.   

y

  Disconnect main power before replacement or servicing.   

y

  Make sure there is no flammable materials close to the unit while operating as it is fire 

hazard.  

y

  Use safety cable when fixes this unit. Don’t handle the unit by taking its head only, but 

always by taking its base.     

y

 Maximum ambient temperature is ta: 40

. Don’t operate it where the temperature is 

higher than this. 

y

  Unit surface temperature may reach up to 85

. Don’t touch the housing bare-hand during 

its operation. Turn off the power and allow about 15 minutes for the unit to cool down 

before replacing or serving. 

y

  In the event of serious operating problem, stop using the unit immediately. Never try to 

repair the unit by yourself. Repairs carried out by unskilled people can lead to damage or 

malfunction. Please contact the nearest authorized technical assistance center. Always 

use the same type spare parts. 

y

 

Do not touch any wire during operation as high voltage might be causing electric shock.

 

Warning 

y

  To prevent or reduce the risk of electrical shock or fire, do not expose the unit to rain or 

moisture. 

y

  Do not open the unit within five minutes after switching off. 

Please read carefully the instruction, which includes important information 

about the installation, usage and maintenance. 

Содержание Kudos 108

Страница 1: ...19 Innovation Quality Performance elumen8 Kudos 108 User Guide Professional Entertainment Technology ...

Страница 2: ... Clean with soft cloth using normal glass cleaning fluid y Always dry the parts carefully y Clean the external optics at least every 20 days Clean the internal optics at least every 30 60 days EC Declaration of Conformity We declare that our products lighting equipments comply with the following specification and bears CE mark in accordance with the provision of the Electromagnetic Compatibility E...

Страница 3: ... Unpack and check carefully there is no transportation damage before using the unit y Before operating ensure that the voltage and frequency of power supply match the power requirements of the unit y It s important to ground the yellow green conductor to earth in order to avoid electric shock y The unit is for indoor use only Use only in a dry location y The unit must be installed in a location wi...

Страница 4: ... power consumption Super compact low weight Voltage 100V 240V 50 60Hz Fuse T 6 3A Power consumption 120W Light source 3W LED x 36 R8 G10 B10 W8 Dimension 304 x 267 x 167 mm Weight 5 7kgs 16 4 5 DMX512 Connection 1 If you using a controller with 5 pins DMX output you need to use a 5 to 3 pin adapter cable 2 At last unit the DMX cable has to be terminated with a terminator Solder a 120 ohm 1 4W resi...

Страница 5: ... the selected functions LED DMX On DMX input present MASTER On Master Mode SLAVE On Slave Mode SOUND Flashing Sound activation Button MENU To select the programming functions DOWN To go backward in the selected functions UP To go forward in the selected functions ENTER To confirm the selected functions ...

Страница 6: ...ction To select any of the given functions press the MENU button up to when the required one is showing on the display Select the function by ENTER button and the display will blink Use DOWN and UP button to change the mode Once the required mode has been selected press the ENTER button to setup to go back to the functions without any change press the MENU button again Hold and press the MENU butt...

Страница 7: ... UP button to change the DMX512 address Once the address has been selected press the ENTER button to setup to go back to the functions without any change press the MENU button again Hold and press the MENU button about one second or wait for one minute to exit the menu mode Please refer to the following diagram to address your DMX512 channel for the first 4 units Channel mode Unit 1 Address Unit 2...

Страница 8: ...und State press the ENTER button to confirm present mode will blink on the display Use the DOWN and UP button to select the On sound on or Off sound off mode Once the mode has been selected press the ENTER button to setup to go back to the functions without any change press the MENU button again Hold and press the MENU button about one second or wait for one minute to exit the menu mode 12 4 1 Mas...

Страница 9: ... to select the 0 100 mode Once the mode has been selected press the ENTER button to setup to go back to the functions without any change press the MENU button again Hold and press the MENU button about one second or wait for one minute to exit the menu mode Pan Inverse Select Pan Inverse press the ENTER button to confirm present mode will blink on the display Use the DOWN and UP button to select t...

Страница 10: ...e Press the MENU button up to when the Temperature Test is blinking on the display Pressing ENTER button and the display will show the temperature of the unit To go back to the functions press the MENU button again Hold and press the MENU button about one second or wait for one minute to exit the menu mode Fixture Time Press the MENU button up to when the Fixture Time is blinking on the display Pr...

Отзывы: