When an IAM (the SS7 protocol) or SETUP (the PRI protocol) message received with redirection
information—the number from the
Redirecting Number
field.
–
When message 302 (the SIP protocol) is received—the number from the
To
field.
When the
Save Redirection Tag
checkbox is checked, the following field is added for redirected calls:
;2013-10-09 17:58:26;5;16;user answer;192.168.0.2;trunk-
SIP;TrunkGroup01;650000;650000;1;1;001;001;0.0.0.0;trunk-SS7;TrunkGroup00;650023;650023;2013-10-09
17:58:24;2013-10-09 17:58:31;
redirecting
;
where
redirecting
—a redirection tag.
The redirection tag may have the following values:
redirecting
—the caller has redirected the call to the callee;
redirected
—the call initiated by the caller has been redirected to another subscriber.
4.1.5
E1 Streams
This section
6
describes configuration of signalling and parameters for each E1 stream.
4.1.5.1
Signalling Protocol Selection
To select a signalling protocol for a stream, use the
Signalling Protocol
drop-down list.
The device supports the following signalling protocols:
Q.931 (User, Network);
SS7 (ОКС-7);
QSIG for subscriber name transmission;
CorNet for subscriber name transmission.
4.1.5.2
Configuration of Physical Parameters
Physical settings
Enable
—the stream is physically enabled.
CRC4 xmit/control
—CRC4 checksum is generated
during transmission and checked during reception.
Equalizer
—when
checked,
amplifies
the
transmitted signal.
Alarm indication
—when checked, a local stream
fault results in fault indication (the ALARM LED
turns on and the alarm is registered in the alarm
log).
Remote alarm indication
—when checked, a
remote stream fault results in fault indication (the
6
Only one E1 stream is available in an SMG-2 device by default. To activate another one, a special licence is required. For
more information about licences, see section
4.1.19
Licence Renewal