167
normal
level timer (x100 ms)
set
mtp2
T4
emergency
<TIMER>
4-6
Set a value of MTP2 T4
emergency level timer (x100 ms)
set mtp2 T6
<TIMER>
30-60
Set a value of MTP2 T6 level
timer (x100 ms)
set
mtp2
T7
normal
<TIMER>
5-20
Set a value of MTP2 T7 normal
level timer (x100 ms)
set mtp3 T2
<TIMER>
7-20
Set a value of MTP3 T2 level
timer (x100 ms)
set mtp3 T4
<TIMER>
5-12
Set a value of MTP3 T4 level
timer (x100 ms)
set mtp3 T12
<TIMER>
8-15
Set a value of MTP3 T12 level
timer (x100 ms)
set mtp3 T13
<TIMER>
8-15
Set a value of MTP3 T13 level
timer (x100 ms)
set mtp3 T14
<TIMER>
20-30
Set a value of MTP3 T14 level
timer (x100 ms)
set mtp3 T17
<TIMER>
8-15
Set a value of MTP3 T17 level
timer (x100 ms)
set mtp3 T22
<TIMER>
1800-3600
Set a value of MTP3 T22 level
timer (x100 ms)
set mtp3 T23
<TIMER>
1800-3600
Set a value of MTP3 T23 level
timer (x100 ms)
set isup T1
<TIMER>
150-600
Set a value of ISUP T1 level timer
(x100 ms)
set isup T5
<TIMER>
3000-9000
Set a value of ISUP T5 level timer
(x100 ms)
set isup T6
<TIMER>
100-600
Set a value of ISUP T6 level timer
(x100 ms)
set isup T7
<TIMER>
200-300
Set a value of ISUP T7 level timer
(x100 ms)
set isup T8
<TIMER>
150-600
Set a value of ISUP T1 level timer
(x100 ms)
set isup T9
<TIMER>
300-2400
Set a value of ISUP T9 level timer
(x100 ms)
set isup T12
<TIMER>
150-600
Set a value of ISUP T12 level
timer (x100 ms)
set isup T13
<TIMER>
3000-9000
Set a value of ISUP T13 level
timer (x100 ms)
set isup T14
<TIMER>
150-600
Set a value of ISUP T14 level
timer (x100 ms)
set isup T15
<TIMER>
3000-9000
Set a value of ISUP T15 level
timer (x100 ms)
set isup T16
<TIMER>
150-600
Set a value of ISUP T16 level
timer (x100 ms)
set isup T17
<TIMER>
3000-9000
Set a value of ISUP T17 level
timer (x100 ms)
set isup T18
<TIMER>
150-600
Set a value of ISUP T18 level
timer (x100 ms)
set isup T19
<TIMER>
3000-9000
Set a value of ISUP T19 level
timer (x100 ms)
set isup T20
<TIMER>
150-600
Set a value of ISUP T20 level
timer (x100 ms)
set isup T21
<TIMER>
3000-9000
Set a value of ISUP T21 level
timer (x100 ms)
set isup T22
<TIMER>
150-600
Set a value of ISUP T22 level
timer (x100 ms)
set isup T23
<TIMER>
3000-9000
Set a value of ISUP T23 level