Electrical Safety Requirements
Prior to connecting the device to a power source, ensure that the equipment case is grounded with an
earth bonding point. The earthing wire should be securely connected to the earth bonding point. The
resistance between the earth bonding point and earthing busbar should be less than 0,1
Ω
. PC and
measurement instruments should be grounded prior to connection to the terminal. The potential
difference between the equipment case and the cases of the instruments should be less than 1V.
Prior to turning the device on, ensure that all cables are undamaged and securely connected.
Make sure the device is off, when installing or removing the case.
Follow the instructions given in
to install or remove SFP transceivers. This
operation does not require the terminal to be turned off.
2.7.3 Terminal installation
Check the device for visible mechanical damage before installing and turning it on. In case of any damage,
stop the installation, fill in a corresponding document and contact your supplier. If the terminal was exposed to
low temperatures for a long time before installation, leave it for 2 hours at ambient temperature prior to
operation. If the device was exposed to high humidity for a long time, leave it for at least 12 hours in normal
conditions prior to turning it on.
Support brackets mounting
The delivery package includes support brackets for rack installation and mounting screws to fix the terminal
case on the brackets. To install the support brackets:
Step 1.
Align six mounting holes in the support bracket with the corresponding holes in the side panel of
the device.
Step 2.
Use a screwdriver to screw the support bracket to the case.
Step 3.
Repeat steps 1 and 2 for the second support bracket.
Figure 5 – Support brackets mounting
Terminal rack installation
To install the terminal to the rack:
Step 1.
Attach the terminal to the vertical guides of the rack.
Step 2.
Align mounting holes in the support bracket with the corresponding holes in the rack guides. Use
the holes of the same level on both sides of the guides to ensure the device horizontal installation.
Step 3.
Use a screwdriver to screw the terminal to the rack.