5.2.4.4 Management profile configuration
In the management profile it is possible to configure parameters to control a device configured in the RG
domain. There are two options for transmitting the configuration for ACS settings – via OMCI; receive in other
ways (for example via DHCP opt43).
Step 1.
Set the
iphost id
to the value set in the cross-connect profile.
Step 2.
Set the ACS configuration obtainment mode by using the
omci-configuration enable
command.
Step 3.
When transmitting parameters via OMCI. Set parameters for ACS:
username, password
and
url.
5.2.4.5 ONT configuration procedure
Figure below shows a step-by-step procedure of ONT configuration.
Figure 19 – ONT configuration procedure
Step 1.
Prior to proceed to ONT configuration, add an ONT into the OLT configuration. For an ONT to be
added and configured, it does not need to be physically connected to the OLT. You can view the list of
inactive ONTs with the help of the
show interface ont <gpon-port> unactivated
command.
LTP-16N# show interface ont 1 unactivated
-----------------------------------
GPON-port 5 ONT unactivated list
-----------------------------------
## Serial ONT ID GPON-port RSSI Status
1 ELTX0600003D n/a 5 n/a unactivated