![Eltek Valere Minipack Скачать руководство пользователя страница 34](http://html1.mh-extra.com/html/eltek-valere/minipack/minipack_quick-start-manual-and-manual_2397275034.webp)
Quick Start Guide
Minipack PS System
356808.103, 1v2-2008-10
26
I/O Monitor CAN Node
The
I/O
Monitor
CAN Bus Node
enables you to decentralize and
increase the number of input
monitoring and output controlling
signals in your
Smartpack
based DC
power supply system. Also, it
monitors and controls the
compartment temperature inside fan-
cooled outdoor cabinets.
Read also the “Installation Guide
I/O Monitor CAN Node”, document
351503.033.
Appendix
CAN Bus Nodes
CAN port 1&2
Electrically identical
DIP switches
CAN ID address
DIP switch #1
I/O Monitor
Power
LED Lamp (green)
Warning
LED Lamp (yellow)
Alarm
LED Lamp (red)
Configurable Inputs
Terminal Block X*
Input 6
Relay Outputs
Terminal Block X**
Relay 1
I/O Monitor
Fan Control Inputs & Outputs
Terminal Block X***
Pin 1
DIN Rail
mounting
clips
Screw head
mounting slot (2x)
(Head’s diameter >5 mm
and <8 mm)
I/O Monitor Connections
Voltage free relay outputs and Configurable monitoring inputs
FUNCTION
SIGNAL PIN-OUT
I/O Monitor
To next
CAN bus node
CAN
port 1&2
RJ45, 8 pins
From p
revious
CAN bus node
O
r
R
J45 C
A
N
b
u
s t
e
rm
ina
tion pl
ug, i
f th
e I/O
Mo
n
ito
r is the
la
st
n
ode
in
th
e
CA
N
b
u
s
(Customer Connections)
1.5 mm
2
, max.
wire section
DIP
Switches
(5-8 always
OFF)
1
2
3
4
Out
In
(T
o and
fr
om
exter
nal fa
ns
+
−
+
−
Temperature Sense 1
4
3
2
1
5
8
7
6
X:***
Temperature Sense 2
Temperature
Sensor 1
Temperature
Sensor 2
Tachometer Input 1
Tachometer Input 2
Fan Speed Monitor 1
Fan Speed Monitor 2
Speed Control Output 1
Speed Control Output 2
Fan Speed Control 1
Fan Speed Control 2
Fan C
o
n
trol
Inpu
ts &
Ou
tp
ut
s
Alarm Circuit 1
Alarm Circuit 2
Alarm Circuit 3
Alarm Circuit 4
Relay 4
(T
o exter
nal
e
q
ui
pm
en
t)
NO
NC
C
NO
C
NC
C
NO
NC
NO
C
NO
NC
C
NC
X:**
NO
C
NC
–
+
Relay 1
Relay 2
Relay 3
Relay 5
Relay 6
Alarm Circuit 5
Alarm Circuit 6
(To be shorted)
Not in use
Alarm Rel
ay Ou
tpu
ts
Input Circuit 1
Input Circuit 2
Input Circuit 3
Input Circuit 4
6
Config. Input
(F
ro
m
exter
nal
equi
pm
ent)
3
2
1
4
5
Config. Input
Config. Input
Config. Input
Config. Input
Config. Input
Input Circuit 5
Input Circuit 6
+
–
+
–
–
–
+
–
+
+
+
–
X:*
Program
mabl
e I
npu
ts
I/O
Monitor
ID
#
DIP Switch Position
1
⎯
2
⎯
3
⎯
4
1
st
Monitor
81
OFF
⎯
OFF
⎯
OFF
⎯
OFF
2
nd
Monitor
82
ON
⎯
OFF
⎯
OFF
⎯
OFF
3
rd
Monitor
83
OFF
⎯
ON
⎯
OFF
⎯
OFF
4
th
Monitor
84
ON
⎯
ON
⎯
OFF
⎯
OFF
5
th
Monitor
85
OFF
⎯
OFF
⎯
ON
⎯
OFF
6th Monitor
86
ON
⎯
OFF
⎯
ON
⎯
OFF
7
th
Monitor
87
OFF
⎯
ON
⎯
ON
⎯
OFF
8
th
Monitor
88
ON
⎯
ON
⎯
ON
⎯
OFF
9
th
Monitor
89
OFF
⎯
OFF
⎯
OFF
⎯
ON
10
th
Monitor
90
ON
⎯
OFF
⎯
OFF
⎯
ON
11
th
Monitor
91
OFF
⎯
ON
⎯
OFF
⎯
ON
12
th
Monitor
92
ON
⎯
ON
⎯
OFF
⎯
ON
13
th
Monitor
93
OFF
⎯
OFF
⎯
ON
⎯
ON
14
th
Monitor
94
ON
⎯
OFF
⎯
ON
⎯
ON
I/O Monitor
DIP switch configuration
ID <81>
(All switches OFF)
Note:
•
DIP switch
positions 5
through 8 are
always to be OFF
•
The monitor’s
ID # corresponds
to the DIP
switch’s binary
value plus 81
Содержание Minipack
Страница 17: ...PULLOUT Check Lists Pullout Pull out the pages with the gray outer band and use them as check lists...
Страница 20: ......
Страница 22: ...PULLOUT...
Страница 24: ...PULLOUT Check Lists Pullout Pull out the pages with the gray outer band and use them as check lists...
Страница 35: ...Quick Start Guide Minipack PS System 356808 103 1v2 2008 10 27...
Страница 36: ...Quick Start Guide Minipack PS System 356808 103 1v2 2008 10 28...
Страница 39: ...Quick Start Guide Minipack PS System 356808 103 1v2 2008 10 31...