Remote switch system FTS14
Overview of telegrams:
Derive telegram between wireless pushbuttons, inputs FTS14EM, bus users and signal code
The 10 inputs of input module FTS14EM generate 5 or 10 different control telegrams which are derived from the wireless pushbut-
ton. The operating mode is dependent on the lower rotary switch (UT or RT).
Operating mode UT (universal pushbutton)
In UT mode, the FTS14EM generates a consecutive ID for each of the 10 terminals and their ID range is dependent on a combina-
tion of the two rotary switch positions. In addition, the signal generated also contains a code for the rocker half or rocker end de-
rived from the wireless pushbutton. This must be considered when programming manually with PCT14.
Example:
ID
Input
Rocker half
Rocker end
0000100
1
E1
right
top
0000100
2
E2
right
bottom
0000100
3
E3
left
top
0000100
4
E4
left
bottom
0000100
5
E5
right
top
0000100
6
E6
right
bottom
0000100
7
E7
left
top
0000100
8
E8
left
bottom
0000100
9
E9
right
top
000010
10
E10
right
bottom
Rocker top right
Signal code: 70
Input: E1; E5; E9
Scene: 2
Bus user T2
Rocker top left
Signal code: 30
Input: E3; E7
Scene: 1
Bus user T1
Rocker bottom left
Signal code: 10
Input: E4; E8
Scene: 3
Bus user T3
Rocker bottom right
Signal code: 50
Input: E2; E6; E10
Scene: 4
Bus user T4