13
Transmission protocol
Wind Sensor KNX W
• Date of issue: 31.10.2012 • Technical changes reserved. Errors reserved.
5. Transmission protocol
Units of measurement:
Wind in metre per second
5.1. List of all communication objects
EIS types:
1
Switching 1/0
5
Floating point value
6
8 bit value
Abbreviations Flags:
C
Communication
R
Read
W Write
T
Transmit
No.
Name
Function
EIStype
Flags
0
Wind force measured value
Output
5
C R T
1
Request maximum wind force
Input
1
C R W
2
Maximum wind force
measured value
Output
5
C R T
3
Reset maximum wind force
Input
1
C R W
4
Wind sensor malfunction
Output
1
C R T
5
Wind threshold value 1
16 bit value
5
C R W T
6
Wind threshold value 1
1 = Increment |
0 = Decrement
1
C R W
7
Wind threshold value 1
Increment
1
C R W
8
Wind threshold value 1
Decrement
1
C R W
9
Wind threshold value 1
Switching output
1
C R T
10
Wind threshold value 1
Switching output
block
1
C R W
11
Wind threshold value 2
16 bit value
5
C R W T
12
Wind threshold value 2
1 = Increment |
0 = Decrement
1
C R W
13
Wind threshold value 2
Increment
1
C R W
14
Wind threshold value 2
Decrement
1
C R W
15
Wind threshold value 2
Switching output
1
C R T
16
Wind threshold value 2
Switching output
block
1
C R W
17
Wind threshold value 3
16 bit value
5
C R W T
18
Wind threshold value 3
1 = Increment |
0 = Decrement
1
C R W