16
Transfer protocol
Brightness and Wind Sensor KNX LW sl
• Status: 19.08.2021 • Errors excepted. Subject to technical changes.
228
Twilight brightness threshold value 3:
(1:+ | 0:-)
Input
-WC-
[1.1] DPT_Switch
1 bit
229
Twilight brightness threshold 3: delay
from 0 to 1
Input
-WC-
[7.5] DPT_TimePeriod-
Sec
2 bytes
230
Twilight brightness threshold 3: delay
from 1 to 0
Input
-WC-
[7.5] DPT_TimePeriod-
Sec
2 bytes
231
Twilight brightness threshold value 3:
Switching output
Output
R-CT
[1.1] DPT_Switch
1 bit
232
Twilight brightness threshold value 3:
Switching output block
Input
-WC-
[1.1] DPT_Switch
1 bit
234
Twilight brightness threshold value 4:
Absolute value
Input/
Output
RWCT [9.4] DPT_Value_Lux
2 bytes
235
Twilight brightness threshold value 4:
(1:+ | 0:-)
Input
-WC-
[1.1] DPT_Switch
1 bit
236
Twilight brightness threshold 4: delay
from 0 to 1
Input
-WC-
[7.5] DPT_TimePeriod-
Sec
2 bytes
237
Twilight brightness threshold 4: delay
from 1 to 0
Input
-WC-
[7.5] DPT_TimePeriod-
Sec
2 bytes
238
Twilight brightness threshold value 4:
Switching output
Output
R-CT
[1.1] DPT_Switch
1 bit
239
Twilight brightness threshold value 4:
Switching output block
Input
-WC-
[1.1] DPT_Switch
1 bit
251
Night: Switching output
Output
R-CT
[1.1] DPT_Switch
1 bit
252
Night: Switching delay on night
Input
-WC-
[7,005] DPT_TimePeri-
odSec
2 bytes
253
Night: Switching delay on day
Input
-WC-
[7,005] DPT_TimePeri-
odSec
2 bytes
271
Wind sensor: Malfunction
Output
R-CT
[1.1] DPT_Switch
1 bit
272
Wind sensor: Measurement [m/s]
Output
R-CT
[9.5] DPT_Value_Wsp
2 bytes
273
Wind sensor: Measurement [Beaufort]
Output
R-CT
[20.014] DPT_Beau-
fort_Wind_Force_S-
cale
1 byte
274
Wind sensor: Max. query measure-
ment
Input
-WC-
[1.017] DPT_Trigger
1 bit
275
Wind sensor: Maximum measurement
[m/s]
Output
R-CT
[9.5] DPT_Value_Wsp
2 bytes
276
Wind sensor: Maximum measurement
[Beaufort]
Output
R-CT
[20.014] DPT_Beau-
fort_Wind_Force_S-
cale
1 byte
277
Wind sensor: Max. reset measurement Input
-WC-
[1.017] DPT_Trigger
1 bit
281
Wind threshold value 1: Absolute value Input/
Output
RWCT [9.5] DPT_Value_Wsp
2 bytes
282
Wind threshold value 1: (1:+ | 0:-)
Input
-WC-
[1.1] DPT_Switch
1 bit
283
Wind threshold value 1: Delay from
0 to 1
Input
-WC-
[7.5] DPT_TimePeriod-
Sec
2 bytes
284
Wind threshold value 1: Delay from
1 to 0
Input
-WC-
[7.5] DPT_TimePeriod-
Sec
2 bytes
285
Wind threshold value 1: Switching out-
put
Output
R-CT
[1.1] DPT_Switch
1 bit
No.
Text
Function Flags
DPT type
Size