20
Parameter setting
Actuator KNX S1R-B4 compact
• Version: 12.09.2022 • from application 1.0 • Technical changes and errors excepted.
Use movement limit 1/2:
The movement limits are activated here, and can them be configured in their own
menu items. See ‘Movement limits’ on Page 30.
Short time restriction (for blinds):
If short time restriction is active, only short time movement commands are still
possible manually. If the function "Allow step commands only for blind adjustment" is
activated simultaneously, (see
, page 15) only the slats can
still be adjusted by hand but no longer the movement position of the shutter.
Restriction is active for object value 1.
Use block 3
• no
• yes, with blocking object
• yes, as wind blocking
• yes, as rain blocking
Use block 4
• no
• yes, with blocking object
• yes, as wind blocking
• yes, as rain blocking
Use Block 5 (low priority)
• no
• yes, with blocking object
• yes, as wind blocking
• yes, as rain blocking
Priority is
• Block 5 over Manual
• Manual over Block 5
Use monitoring of blocking objects
No • Yes
Monitoring period for blocking objects
(only if using monitoring of the blocking
objects)
5s... • 2 h; 5 min
Behaviour if a blocking object is not
received
(only if blocking object monitoring is used)
• Stop
• Up command • Down command
(Shutters/roller blinds)
• Retract command • Extend command
(Awnings)
• Close command • Open command
(Windows)
Use short time limit
no • yes
Value of the object in front of 1.
communication and bus voltage
restoration
(if short time restriction is used)
0 • 1
Содержание 70550
Страница 1: ...EN Installation and Adjustment KNX S1R B4 compact Multifunctional Actuator Item number 70550...
Страница 2: ......
Страница 51: ......