Parameter setting

Actuator KNX S1R-B4 compact

 • Version: 12.09.2022 • from application 1.0 • Technical changes and errors excepted.

Drive channel A is Master, zero position sensor via bus,
drive channel B is Slave, zero position sensor via bus:

5.2.3. Channel settings – switch functions

If two switchable devices are connected to the output channel, two separate channels
will appear (e.g. "Channel A1 – switch function" and "Channel A2 – switch function").
First set the general specifications for the connected device and, if necessary, activate
the connections, time functions and blocking objects. A diagram is found in chapter 

Channel settings – switch functions

, page 44.

Relay operation

closer •  opener

Behavior after reset and ETS download

• opened
• closed

Use status object

• no
• as an active feedback object
• as a passive status object

Use connection function
(see 

Connection (switch functions)

, page 

45)

no • yes

Use time function
(see 

On/Off switch delays, time switching 

(switch functions)

, page 45)

• no
• as a switch on delay
• as a switch off delay
• as a switch on and off delay
• as a staircase light timer

Use blocking object

no • yes

Use scenes

no • yes

zero position

zero position 

of drive 1

of drive 2

Master

Drive 1

at channel A

Slave

Drive 2

at channel B

Master command

Master zero position status

Slave zero position status

68

67

71

70

  69

72

Zero position reached

  65

65

sensor

sensor

Содержание 70550

Страница 1: ...EN Installation and Adjustment KNX S1R B4 compact Multifunctional Actuator Item number 70550...

Страница 2: ......

Страница 3: ...ation objects 6 5 Parameter setting 14 5 1 General settings 14 5 2 Output 14 5 2 1 Channel settings drives 15 5 2 1 1 Control drives 17 5 2 1 2 Manual 25 5 2 1 3 Automation external 25 5 2 1 4 Automat...

Страница 4: ...n this manual Safety advice Safety advice for working on electrical connections components etc DANGER indicates an immediately hazardous situation which will lead to death or severe injuries if it is...

Страница 5: ...mbled condition and after conclusion of all installation and operational start up tasks and only in the sur roundings designated for it Elsner Elektronik is not liable for any changes in norms and sta...

Страница 6: ...tion of two switchable devices light fan 4 binary inputs Position feedback movement position also slat position for shutters Position storage movement position via 1 bit object storage and call up e g...

Страница 7: ...ual address 15 15 255 This can be changed via the ETS A button and a control LED are located on the unit for this purpose 3 2 Monitor safety functions For KNX devices with safety functions e g wind or...

Страница 8: ...RWC 5 1 DPT_Scaling 1 Byte 5 Channel A Manual blind position Input RWC 5 1 DPT_Scaling 1 Byte 6 Channel A Automatic extended Input RWC 1 8 DPT_UpDown 1 Bit 7 Channel A Automatic short time Input RWC 1...

Страница 9: ...annel A Outdoor temperature blocking status Output R CT 1 1 DPT_Switch 1 Bit 25 Channel A Twilight object Input RWC 1 1 DPT_Switch 1 Bit 26 Channel A Twilight measurement Input RWC 9 4 DPT_Value_Lux 2...

Страница 10: ...Channel A Cold air intake outside temp measurement value Input RWC 9 1 DPT_Value_Temp 2 Bytes 47 Channel A Cold air intake blocking status Output R CT 1 1 DPT_Switch 1 Bit 48 Channel A Forced ventilat...

Страница 11: ...Bit 65 Channel A Zero position reached Input RWC 1 1 DPT_Switch 1 Bit 66 Channel A Zero position sensor disrupted Output R CT 1 1 DPT_Switch 1 Bit 67 Channel A Master zero position status Output R CT...

Страница 12: ...king 3 Wind blocking object Input RWC 1 1 DPT_Switch 1 Bit 87 Channel A Blocking 3 Wind blocking measurement Input RWC 9 5 DPT_Value_Wsp 2 Bytes 88 Channel A Blocking 3 Wind blocking status Output R C...

Страница 13: ...Bit 108 Channel A1 Start stop staircase light function Input RWC 1 10 DPT_Start 1 Bit 109 Channel A1 Link Input RWC 1 2 DPT_Bool 1 Bit 110 Channel A1 Call up saving scenes Input RWC 18 1 DPT_SceneCon...

Страница 14: ...utput R CT 5 5 xxx 1 Byte 138 Input 2 Temperature encoder Output R CT 9 1 DPT_Value_Temp 2 Bytes 139 Input 2 Brightness encoder Output R CT 9 4 DPT_Value_Lux 2 Bytes 140 Input 2 Scene Output R CT 18 1...

Страница 15: ...dimming Input Output RWCT 3 7 DPT_Control_ Dimming 4 Bit 167 Input 4 Encoder 8 Bit Output R CT 5 5 xxx 1 Byte 168 Input 4 Temperature encoder Output R CT 9 1 DPT_Value_Temp 2 Bytes 169 Input 4 Bright...

Страница 16: ...positions that were stored by the user with the memory function via the bus are retained If a value is changed via the bus not in the ETS then this value is retained with only changed parameters 5 2...

Страница 17: ...nnected to the output channel set first the general specifications for the drive Driving direction Up down on off or open close can be exchanged Runtime The runtime between the end positions is the ba...

Страница 18: ...a change of direction of the drive should be adjusted according to the specifications of the motor manufacturer Reference movement With the regular movement to the two end positions the runtime and ze...

Страница 19: ...open One of two drive mechanisms is prioritised and is parameterised as master and the other one as slave By means of zero position sensors both actuators know the own current status and the current s...

Страница 20: ...ing not safe position and therefore submits a master command to the awning This is the signal for the awning to retract a little bit As soon as the awning has reached a safe position there is an accor...

Страница 21: ...ge 21 Block wind blocking page 22 and Block rain blocking page 23 The priorities of the blocking objects correspond to the sequence listed Block 1 has the highest priority Block 5 the lowest Zero posi...

Страница 22: ...active for object value 1 Use block 3 no yes with blocking object yes as wind blocking yes as rain blocking Use block 4 no yes with blocking object yes as wind blocking yes as rain blocking Use Block...

Страница 23: ...e 31 appears Block blocking objects The menu item only appears if a block with blocking object was configured for control Here it is specified was happens for object value 1 and 0 Via the free blockin...

Страница 24: ...p move into position up command down command shutter blind retract command extend command awning close command open command window Position in only if by using a block a specific position is achieved...

Страница 25: ...position in min after blocking 1 255 5 Behaviour after waiting period For manual operation before and after blocking no action move into last position For automatic operation after blocking follow aut...

Страница 26: ...command open command window Position in only if by using a block a specific position is achieved 0 100 Slat position in only if by using a block a specific shutter position is achieved 0 100 Waiting p...

Страница 27: ...itions for object values 0 and 1 is selected the position for object value 0 is retrieved The stored positions can be changed via the learning object The learning object ensures that the current posit...

Страница 28: ...an a threshold value as well as a 16bit object measurement value 1 bit input object Shading is allowed if the bit is 0 and blocked if the bit is 1 16 bit input object Shading is allowed if the measure...

Страница 29: ...ked if the measurement value is smaller than the target value hysteresis difference Automatic shading The automatic shading evaluates the input objects brightness and position of the sun of a weather...

Страница 30: ...ons change quickly Threshold value per communication object The threshold value is received via the communication object and can be changed additionally e g button for more sensitive and less sensitiv...

Страница 31: ...fting lowering with two comm objects Hysteresis threshold in percent kLux Hysteresis in 0 100 10 Hysteresis in kLux 1 120 20 Increments in klux only when lifting lowering with comm object 1 5 2 Drive...

Страница 32: ...ing the position reached Saving occurs for value 1 and can for example be realized via a button linked to the teaching object Numerical specifications already set are overwritten by the teaching objec...

Страница 33: ...ject Ventilation is allowed if the bit is 0 and blocked if the bit is 1 16bit input object Ventilation is allowed if the measurement value is larger than the threshold value hysteresis and blocked if...

Страница 34: ...if the outdoor measurement value is greater than or equal to the target value difference Open by temperature humidity Indoor temperature These parameters appear if ventilated at too high temperature t...

Страница 35: ...t 1 bit Type of temperature input object 16 bit Indoor temperature of threshold specification via parameter communication object Indoor temperature of threshold specification via parameter Indoor temp...

Страница 36: ...f the ventilation is controlled by temperature and humidity via a 16bit input object then you can either set an opening position or open the windows incrementally In the step operation the temperature...

Страница 37: ...vement positions Activate a scene save point Assign a scene number to the scene save point Use this scene number to call save the movement position stored in the actuator Make sure that every scene nu...

Страница 38: ...y which value is sent when pressing releasing the button and when it will be sent The input can be blocked using a blocking object Set what is transmitted to the bus when de activating blocking For ac...

Страница 39: ...ption of the setting options for the individual control modi can be found in the general part of chapter Control modi for drive control page 40 The input can be blocked using a blocking object For act...

Страница 40: ...put as temperature encoder If the input is used as a temperature encoder then choose the bus function Temperature encoder and specify which value between 30 C and 80 C will be sent By sending a temper...

Страница 41: ...ng a blocking object For active blocking there is no bus communication Input as actuator button If this channel is used for the input to the control of the drive then specify the button function and t...

Страница 42: ...or windows then different control modi can be set Standard If briefly operated the drive will move incrementally or stops If operated longer the drive will move up to the end position The time differe...

Страница 43: ...ps as soon as the button is released Time between short and long in 0 1 seconds 1 50 10 Repeat the step command for a long button press every 0 1 s every 2 sec every 0 5 sec Point in time 0 Actuate of...

Страница 44: ...ommunication object numbers refer to the mutual master slave coupling of drives at the output channel A and channel B Actuator A is Master zero position sensor at input 1 of the actuator Actuator B is...

Страница 45: ...o position sensor at input 1 of the actuator IN 1 zero position zero position Master Drive 1 at channel A Slave Drive 2 at channel B Master command Master zero position status Slave zero position stat...

Страница 46: ...cts A diagram is found in chapter Channel settings switch functions page 44 Relay operation closer opener Behavior after reset and ETS download opened closed Use status object no as an active feedback...

Страница 47: ...timer function makes sure for example that the light is on for a defined period of time and then turns off automatically Switch on delay The switch on delay is set with a time basis and time factor e...

Страница 48: ...after the blocking is set here The manual operation is then not possible for an active block The function can be used for example for a light which is turned on when pressing a panic button trigger fo...

Страница 49: ...blocked using a blocking object No operation is possible for an active block Correlation connection time switch block Application 1 Staircase light at channel A1 that can only be switchable at twilig...

Страница 50: ...A1 staircase light function start 107 the staircase light time function is activated The time function has priority i e the status triggered by normal switching is overwritten 103 Channel A1 Switching...

Страница 51: ......

Страница 52: ...tronik under Tel 49 0 70 33 30 945 250 or service elsner elektronik de We need the following information to process your service request Type of appliance model name or item number Description of the...

Отзывы: