14.1 Battery Type
The MCS can be used with 2 types of backup batteries, Lead Acid & Lithium-ion.
Default setting is
Lead Acid. Never connect a lithium battery when lead acid mode is selected. Always
select the correct battery type.
Only use Lithium-ion batteries supplied by Elsema.
14.2 Set the Supply Voltage
The control card automatically sets the supply voltage during setup. This option allows you to manually
set the control card to 12 or 24 Volt supply. To use the control card in a solar application you must set
the correct voltage in the Tools. This will disable the automatic voltage sensing which could causes
problems in solar applications.
14.3 Resets Controller
Reset all settings to factory default. Also removes password.
14.4 Test Inputs
This allows you to test all the external devices connected to the controllers inputs. UPPERCASE means
input is activated and lowercase means input is activated.
14.5 Travel Timer for Slip Clutch Motors
This allows you to use the controller with travel time. Used for Slip clutch or Hydraulic Motors
14.8 Slow Speed Ramp Down Time
This allows you to change the time it takes the gate to change its speed from fast to slow.
14.9 Magnetic Limit Switch
Only enable this option when using Elsema’s magnetic Limit Switch.
Menu 14 – Tools
Menu No.
Tools
14.1
Battery Type : Lithium-ion or Lead Acid battery
14.2
Set the Supply Voltage : 12 or 24 Volts
14.3
Resets Controller to Factory Settings
14.4
Test Inputs
14.5
Travel Timer for Slip Clutch Motors
14.6
Solar Gate Mode : Optimises the Control Card for Solar Applications
14.7
Fuse Type : 10 or 15 Amps
Optimises the Control Card for the correct Blade Fuse used
14.8
Slow Speed Ramp Down Time
14.9
Magnetic Limit Switch
14.10
Exit