Menu 6.2 – Courtesy Light Output Mode
The relay output in the courtesy mode can be adjusted from 30 to 300 seconds. This sets the time the
courtesy light is activated. Factory default is 60 seconds.
Menu No.
Courtesy Light Mode
Factory
Default
Adjustable
6.2.1
Courtesy Light Activation
60 seconds
30-300 seconds
6.2.2
Exit
Menu 6.3 – Strobe (Warning) Light Output Mode
The relay output in the strobe (Warning) mode can be configured in different ways:
Menu No.
Strobe (Warning) Light Mode
Factory
Default
Adjustable
6.3.1
Pre-Open Strobe (Warning)
Light Activation
Off
1 – 30 seconds
6.3.2
Pre-Close Strobe (Warning)
Light Activation
Off
1 – 30 seconds
6.3.3
Exit
6.3.1 Pre-Open Strobe Light Activation
This sets the time the strobe light is activated before the gate operates in the open direction. Factory
default is Off.
6.3.2 Pre-Close Strobe Light Activation
This sets the time the strobe light is activated before the gate operates in the close direction. Factory
default is Off.