Menu 6.2 – Courtesy Light Output Mode
The relay output in the courtesy mode can be adjusted from 2 seconds to 18 hours. This sets the time
the courtesy light is activated. Factory default is 1 minute.
Menu No.
Courtesy Light Mode
Factory
Default
Adjustable
6.2.1
Courtesy Light Activation
1 minute
2 seconds to
18 hours
6.2.2
Courtesy Light at Night Only with
LDR Connected
Off
Off/On
6.2.3
Exit
Menu 6.3 – Strobe (Warning) Light Output Mode
The relay output in the strobe (Warning) mode can be configured in different ways:
Menu No.
Strobe (Warning) Light Mode
Factory
Default
Adjustable
6.3.1
Pre-Open Strobe (Warning)
Light Activation
Off
0 – 30 seconds
6.3.2
Pre-Close Strobe (Warning)
Light Activation
Off
0 – 30 seconds
6.3.3
Exit
6.3.1 Pre-Open Strobe Light Activation
This sets the time the strobe light is activated before the gate/door operates in the open direction.
Factory default is Off.
6.3.2 Pre-Close Strobe Light Activation
This sets the time the strobe light is activated before the gate/door operates in the close direction.
Factory default is Off.
20
Double Gate & Door Controller
with Eclipse
®
Operating System (EOS)