Electrical Wiring - Supply, Motors, Battery and Inputs
Always switch off power before doing any wiring.
Make sure that all the wiring is completed and that the motor is connected to the control
card.
Recommended wire strip length should be 12mm for all connections to
the plug in terminal blocks.
The diagram below shows the supply, motors, battery backup and inputs available and the factory default
setting for each input.
If you are using mechanical stops move to the Setup i-Learning Steps. Skip Limit Switch section.
Normally Closed
User can change
Fuse
Relay
Open Close Stop
Open
Limit
Common
Motor 1
Close
Limit
Motor 1
Open
Limit
Motor 2
Close
Limit
Motor 2
Push Button
Open
Close
Stop
Common
PED Access
Photo Beam
LED
AC Supply :
24/12 Volts AC
Model :
MC
Designed by
ELSEMA
IN AUSTRALIA
Normally Closed
User can change
AC Supply
AC Supply
AC Supply
AC Supply
AC Supply
AC Supply
Motor 1
Motor 1
AC Supply
AC Supply
Motor
2
Motor 2
AC Supply
AC Supply
B
Battery -
M
Motor 1
Motor 2
M
Normally
Open
User can change
12 or 24 Volts
AC Supply
9