16.1 Number of Motors
This allows you to manually set the control card to a single motor or a double motor. The control card
will automatically test for motors connected during setup.
16.2 Set the Supply Voltage
This allows you to manually set the control card to 12 or 24 Volt supply. The control card will
automatically set the correct supply voltage during setup. To use the control card in a solar application
you must set the correct voltage in the Tools. This will disable the automatic voltage sensing which
could causes problems in solar applications.
16.3 Resets Controller
Reset all settings to factory default. Also removes password.
16.4 Test Inputs
This allows you to test all the external devices connected to the controllers inputs. UPPERCASE means
input is activated and lowercase means input is deactivated.
16.5 Travel Timer for Slip Clutch Motors
This allows you to use the controller with travel timers. Motor 1 and 2 can have separate travel timers up
to 120 seconds. Used for Hydraulic Motors.
16.9 Slow Speed Ramp Down Time
This allows you to change the time it takes the gate/door to change its speed from fast to slow.
Menu 16 – Tools
Menu No.
Tools
16.1
Number of Motors, Single or Double Gate System
16.2
Set the Supply Voltage : 12 or 24 Volts
16.3
Resets Controller to Factory Settings
16.4
Test Inputs
16.5
Travel Timer for Slip Clutch Motors
16.6
Solar Gate Mode : Optimises the Control Card for Solar Applications
16.7
Fuse Type : 10 or 15 Amps
Optimises the Control Card for the correct Blade Fuse used
16.8
Day and Night Sensitivity Adjustment for the DNS
16.9
Slow Speed Ramp Down Time
16.10
Exit