3E-490044NI – 03/20 

Page 3 

 

EN 

 

 

ELRO-Werke AG 
Wohlerstrasse 47 
5620 Bremgarten 

 

LOCATION 

 

6 AND 10 LEVEL OVENS ON A STAND 

 

The required height of the loading threshold is 900mm.  Fig. 2.1B   
If the  oven  is fitted  with  a  hood  it must  be  fixed  to  the  floor.  The  rear  legs must  be fixed  using  the  two  stainless  brackets  provided  with  the 
stand they should be fitted to the rear legs.  Fig. 2.1C 

 

TWIN CAVITY OVENS 

 

The required height of the loading threshold is 290mm on 6+6 and 6+10 ovens.  Fig. 2.2A  
If the  oven  is fitted  with  a  hood  it must  be  fixed  to  the  floor.  The  rear  legs must  be fixed  using  the  two  stainless  brackets  provided  with  the 
stand they should be fitted to the rear legs

   

Fig. 2.2B 

 

20 LEVEL OVENS AND TWIN CAVITY OVENS 

 

The required height of the loading threshold is 355mm.  Fig. 2.3A   
20  level  GN1/1  ovens must  always  be fixed  to the  floor.  The  oven must  be fixed  to  the  floor  using  the  bracket supplied  with the  oven.  Fit  a 
bracket to the left rear legs.  Fig. 2.3B 

 

INSTRUCTION FOR HOT CONTAINERS 

 
Maximal height for loading is 1600mm from the ground. A sticker is delivered with the instructions manual. Place the sticker on the Combi 
oven at 1600mm from the ground.  
Fig. 8A 
Danger: For containers that are filled with liquid or food that liquefies during the cooking process, operators must be able to see the 

contents of the container if it is inserted any higher. 

 
 

CONNECTIONS 

 

ELECTRICAL CONNECTION 

 

The fixed electrical supply to the unit must incorporate an appropriate isolator that can be locked in the off position. 
All aspects of the installation should be in compliance with current local regulations. 
The appliance must be connected to earth.  
These instructions include recommendations concerning the characteristics and the type of additional protective devices that may 

need to be installed, potentially one or several residual current devices. 

Electric connection is carried out at the rear of the appliance on the right, whatever the model:  Fig. 5A-B 

- Remove the right hand panel. 
- Pull the cable through the gland. 
- Connect the wires (check the neutral and the earth). 
- Tighten the gland. 
- Refit the side panel. 
- Connect the equipotential link to the terminal provided for this purpose.  Fig. 5D 

 Only use H07 RN-F type supply cable sized to suit the load of the unit. (see chapter « technical characteristics » which give the electrical 

rating). 

Provide an approved omnipolar isolation device, (with at least 3 mm clearance between the contacts). 
 

ENERGY ECONOMIZER CONNECTION 

 

6 and 10 level ovens (optional) 
Only use HO 7 RNF type supply cables with a section of 5 x 1.5 mm2. 
A local and approved isolation devise is required for the energy saver (with at least 3mm clearance between all contacts when open). 

Dangerous voltages may be present in the appliance in case of inappropriate installation. 
 

Connection of the energy saver on 20 level units: 
The installation must meet current national statutory provisions (France: NFC 15.100) 
Use H07 RN-F type 1.5mm² cables with the number of cores required by the energy saver. 
Pass the cable(s) through the cable glands on the connector support and through the outer grommets on the electrical support: 

 

 

 

 

Remove the cable bridges B1-C1 and B2-C2 when connecting the energy saver to these terminals. 

 

Содержание PRECIJET+ EPJ061E

Страница 1: ...PRECIJET NOTICE D INSTALLATION FR Fours Mixtes INSTALLATION MANUAL EN Combi Ovens INSTALLATIONSANLEITUNG DE Kombid mpfer MANUAL DE INSTALACION ES Hornos Mixtos 3E 490044NI Ed 03 2020...

Страница 2: ......

Страница 3: ...MANUTENTION MANUTENTION MANTENIMIENTO FOURS 6 ET 10 NIVEAUX 6 AND 10 LEVEL OVENS KOMBID MPFER 6 UND 10 EINSCH BE HORNOS DE 6 Y 10 NIVELES A Fig 1 1A FOURS A 2 ENCEINTES TWIN CAVITY OVENS KOMBID MPFER...

Страница 4: ...3E 490044NI 03 20 Page 2 ELRO Werke AG Wohlerstrasse 47 5620 Bremgarten C Fig 1 2C FOURS 20 NIVEAUX 20 LEVEL OVENS KOMBID MPFER 20 EINSCH BE HORNOS DE 20 NIVELES A Fig 1 3A B Fig 1 3B X5 2 1 1 2...

Страница 5: ...3E 490044NI 03 20 Page 3 ELRO Werke AG Wohlerstrasse 47 5620 Bremgarten C Fig 1 3C D Fig 1 3D x 4 1 2 3 X6 1 2...

Страница 6: ...garten 2 MISE EN PLACE HANDLING AUFSTELLUNG COLOCACI N FOURS 6 ET 10 NIVEAUX SUR SON PIETEMENT 6 AND 10 LEVELS ON A STAND KOMBID MPFER 6 UND 10 EINSCH BE AUF SEINEM UNTERGESTELL HORNOS DE 6 Y 10 NIVEL...

Страница 7: ...20 Page 5 ELRO Werke AG Wohlerstrasse 47 5620 Bremgarten FOURS 6 ET 10 NIVEAUX SUR TABLE 6 AND 10 LEVELS ON A TABLE KOMBID MPFER 6 UND 10 EINSCH BE AUF DEM TISH HORNOS DE 6 Y 10 NIVELES EN TABLA A Fi...

Страница 8: ...0044NI 03 20 Page 6 ELRO Werke AG Wohlerstrasse 47 5620 Bremgarten FOURS A DEUX ENCEINTES TWIN CAVITY OVENS KOMBID MPFER MIT ZWEI GARR UMEN HORNOS DE DOS C MARAS A Fig 2 3A B Fig 2 3B 1 2 8 x 65 1 2 x...

Страница 9: ...3E 490044NI 03 20 Page 7 ELRO Werke AG Wohlerstrasse 47 5620 Bremgarten FOURS 20 NIVEAUX 20 LEVEL OVENS KOMBID MPFER 20 EINSCH BE HORNOS DE 20 NIVELES A Fig 2 3A B Fig 2 3B 1 2 8 x 65 1 x 4 x 1...

Страница 10: ...EAU WATER CONNECTION WASSERANSCHLUSS CONEXI N DE AGUA A Fig 3A 23 C 75 F 4 RACCORDEMENT VIDANGE DRAIN CONNECTION ABLAUFANSCHLUSS CONEXI N VACIADO A Fig 4A AC061KI AC101KI AC20KI 20 27 G3 4 EA EN 13959...

Страница 11: ...G16 HO7RNF 3P T EPJ061G 230 a c 1 3 3G2 5 HO7RNF 1P T N EPJ201G 230 a c 3 3G2 5 HO7RNF 1P T N EPJ101E 400V 3Na c 23 5G4 HO7RNF 3P T N EPJ202E 400V 3Na c 81 3 5G16 HO7RNF 3P T N EPJ101E 230 3a c 38 8 4...

Страница 12: ...se 47 5620 Bremgarten 6 RACCORDEMENT GAZ GAS CONNECTION GASANSCHLUSS CONEXI N GAS A Fig 6A B Fig 6B C Fig 6C P in Pmbar 1 mbar 6 10 Precijet 20 Precijet D Fig 6D 8 mbar P out 11 mbar 6 10 Precijet 20...

Страница 13: ...IT DE NETTOYAGE CLEANING PRODUCT CONNECTION ANSCHLUSS REINIGUNGSMITTEL CONEXI N PRODUCTO DE LIMPIEZA A Fig 7A B Fig 6B 8 CONSIGNES MANIPULATION PLATS CHAUDS GUIDELINES FOR HOT CONTAINERS SICHERHEITSHI...

Страница 14: ...ELRO Werke AG Wohlerstrasse 47 5620 Bremgarten 9 SUPPORT POIGNEE DE CHARIOT 20 NIVEAUX THE 20 LEVELS TROLLEY HANDLE SUPPORT DER RACK GRIFFHALTERUNG 20 EINSCH BE SOPORTE DE MANIJA DE CARRETILLA DE 20...

Страница 15: ...0 Levels GN1 1 Gas ELRO Precijet 20 Ebenen GN1 1 Gas ELRO Precijet 20 Niveles GN1 1 Gas Gaz Gas Gas Gas EPJ202E ELRO Precijet 20 Niveaux GN2 1 Elec ELRO Precijet 20 Levels GN2 1 Elec ELRO Precijet 20...

Страница 16: ...xed next to the data plate which indicates Ein zweites Schild neben dem Typenschild enth lt folgende Angaben Cerca de la placa de identificaci n hay una segunda placa que indica Le gaz pour lequel l a...

Страница 17: ...L PA S Pays Country Land Pa s Cat gorie Categories Kategorie Categor a Gaz Gas Gas Pression Pressure Druck Presi n mbar Autriche Austria sterreich Austria I2H G20 20 I3B P G30 G31 50 I3P G31 50 Finlan...

Страница 18: ...atural gas Erdgas Gas natural G20 20 1 500 148 560 G25 20 1 625 148 568 G25 3 25 1 625 148 568 G P L L P G G P L G31 30 1 360 148 563 G31 37 1 360 148 563 G31 50 1 360 148 563 G30 30 1 335 148 562 G30...

Страница 19: ...de valeur modifier R gler la valeur l aide du codeur Frequence de maintenance Taux d utilisation par jour en heure CAPACITE TRAITEMENT D EAU Ce compteur est valable uniquement si le four est aliment...

Страница 20: ...specter les r gles relatives l enl vement des emballages recyclage ou revalorisation Respecter les r glementations et normes en vigueur du lieu de montage concernant les connexions d eau d lectricit d...

Страница 21: ...ion L installation doit tre conforme aux textes r glementaires nationaux en vigueur L appareil doit tre raccord la terre Les instructions doivent fournir les recommandations concernant les caract rist...

Страница 22: ...type CAa Fours quip s de la fonction lavage automatique avec prise en charge du produit par pompe int gr e selon la norme EN14367 ou EA tous les autres appareils selon la norme EN13959 et conforme la...

Страница 23: ...Appareil osmose inverse ou filtres pour d min ralisation totale BRITA PURITY 1200 Clean ou quivalent R gler le by pass int gr dans le filtre ou utiliser un by pass externe PH 6 5 OK Contr ler la dure...

Страница 24: ...3E 490044NI 03 20 Page 6 FR ELRO Werke AG Wohlerstrasse 47 5620 Bremgarten...

Страница 25: ...able from 1 to 24 hours Select the value to be modified Adjust the value using the coder Frequency of maintenance Level of use per day WATER TREATMENT CAPACITY This only functions if there are 2 separ...

Страница 26: ...l installer or user observes the rules relating to the removal of the packaging recycling or reuse Always comply with current local regulations regarding connecting the unit to water electricity and d...

Страница 27: ...position All aspects of the installation should be in compliance with current local regulations The appliance must be connected to earth These instructions include recommendations concerning the chara...

Страница 28: ...nd the unit are variable Installation connection and commissioning should be undertaken by specialist concessionaires or authorised personnel Nature 168 m filter integral with the oven Provide a local...

Страница 29: ...150 mg l Classical Water softener ion exchanger resin Reverse osmosis device or filters for total demineralization BRITA PURITY 1200 Clean or similar Set the filters integral by pass or use an extern...

Страница 30: ...3E 490044NI 03 20 Page 6 EN ELRO Werke AG Wohlerstrasse 47 5620 Bremgarten...

Страница 31: ...soll Den Wert mithilfe des Drehknopfes einstellen Wartungsintervall Nutzungsrate pro Tag in Stunden KAPAZIT T WASSERAUFBEREITUNG Dieser Z hler ist nur g ltig wenn der Kombid mpfer an 2 separate Wasse...

Страница 32: ...dass die Verpackung der Richtlinie 94 62 CE entspricht Richtlinie ber Verpackungen und Verpackungsabf lle vom 20 12 94 und bittet den Monteur und den Benutzer die Regelungen bez glich der Entsorgung v...

Страница 33: ...n kann ANSCHL SSE ELEKTRISCHER ANSCHLUSS In den festen Leitungen muss gem den Installationsregeln eine Unterbrechungseinrichtung vorgesehen werden die mit einem Verriegelungssystem in der Trennpositio...

Страница 34: ...einem R ckflussverhinderer Bauart EA alle anderen Ger te gem der Norm EN13959 und entsprechend den rtlichen Vorschriften WRAS SVGW DVGW an die Trinkwasserversorgung angeschlossen werden Der Schlauch...

Страница 35: ...der Filter zur Vollentmineralisierung BRITA PURITY 1200 Clean oder gleichwertige Einstellung des im Filter integrierten Bypasses oder Verwendung eines externen Bypasses PH 6 5 OK Kontrolle der Wasserh...

Страница 36: ...3E 490044NI 03 20 Seite 6 DE ELRO Werke AG Wohlerstrasse 47 5620 Bremgarten...

Страница 37: ...ar Ajuste el valor con la ayuda del codificador Frecuencia de mantenimiento ndice de uso diario por horas CAPACIDAD TRATAMIENTO DE AGUA Este contador solo es v lido si el horno est alimentado por 2 re...

Страница 38: ...alajes de 20 12 94 e invita al instalador y al usuario a respetar las reglas relativas a la recogida de los embalajes reciclado y revalorizaci n Respete los reglamentos y normas vigentes en el lugar d...

Страница 39: ...r conforme a los textos reglamentarios nacionales vigentes El aparato debe estar conectado a tierra Las instrucciones deben facilitar las recomendaciones relativas a las caracter sticas y el tipo de d...

Страница 40: ...a hornos equipados con la funci n de lavado autom tico con tratamiento del producto por una bomba integrada de acuerdo con la norma EN14367 o EA el resto de aparatos de acuerdo con la norma EN13959 y...

Страница 41: ...iones Aparato de smosis inversa o filtros para la desmineralizaci n total BRITA PURITY 1200 Clean o equivalente Ajuste el by pass integrado en el filtro o use un by pass externo PH 6 5 OK Controle la...

Отзывы: