6.

Approvals

6.1

ETSI

The standards used in the evaluation of this product establish the threshold values for use in residential 
areas, business and commercial areas as well as in small businesses whereby the use of the product is 
intended for a business environment.
This includes the following, typical sites and spaces:

Residential buildings/living spaces such as houses, apartments and rooms, etc.;

Retail areas such as stores, supermarkets, etc.;

Business premises such as municipal offices, banks, etc..;

Entertainment businesses such as cinemas, public establishments, etc.;

Outdoor locations such as gas stations, parking lots, sports facilities, etc.;

Small business offices such as workshops, service centers, etc.

All areas of application are characterized by the fact that they are connected to the public low-voltage 
power supply. When using in a location in a severely electromagnetically disrupted environment such as 
typical industry environments, problems are likely to occur as a result of the product's inadequate 
interference immunity.

R&TTE Guideline 99/5/EG
EN 300 220-1 V2.1.1 (2006-04) EN 60950-1 (2006-11)
EN 300 220-2 V2.1.2 (2007-06)
EN 301 489-1 V1.8.1 (2008-04)
EN 301 489-3 V1.4.1 (2002-08)
EMV Guideline 2004/108/EG
EN 55022 (2008-05)
EN 50130-4 (2003-09)
EN 50371 (2002-11)
Low Voltage Directive 2006/95/EG
EN 60650-1 (2006-11)
EN 61000-6-1 (2007-10)
EN 61000-6-3 (2007-09)

6.2

Wireless Communication reliability

The communication reliability for the Elpro radio sensor system, often referred to as Quality of service 
(QoS) is based on the following principles:
"The used modulation is of the "Gaussian Frequency-Shift Keying (GFSK)" type. This is a type of 
frequency shift keying modulation that uses a Gaussian filter to smooth positive/negative frequency 
deviations:

- FCC compatible
- Address match for detection of incoming package 
- Automatic retransmission of data packages 
- Automatic CRC and preamble generation
- Build in test function for the radio signal
- Use of frequency  hopping in the 915MHz band
- Limited number of sensors and transmitters used
- Installation requirements

Risk assessment 
for Receivers and 
Transmitters

The Elpro wireless system is made up of a receiver and a transmitter function in the wireless datalogger 
and in each radio sensor. The receivers are divided into three classes, each having its own set of minimum 
performance criteria. The classification is based upon the impact the equipment has on persons in case 
of a failure.
The Elpro radio sensor system complies to a class 2 system:
A failure causes loss of function but not physical risk of a person

Содержание RT2e

Страница 1: ...Wireless Sensor RT2e EL6107E Wireless Sensor RT2e Operation Manual...

Страница 2: ...2 EN Wireless Sensor RT2e EL6107E...

Страница 3: ...sor RT2e 8 3 1 Initial startup 8 3 1 1 Transmitted frequency radio channel 8 3 2 Operation 9 3 3 Maintenance 9 4 Status and error messages 10 5 Technical data 11 5 1 Radio settings 11 5 2 Environment...

Страница 4: ...VED INCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION This product is subject to CE marking The manufacturer guarantees that this product complies with the relevant guidelines EN 61000 6 2 200...

Страница 5: ...internal batteries On the front side there is a status display green red LED and a type label which documents the wireless sensor designation and the ID number of the sensor 1 Aerial 2 Status display...

Страница 6: ...eption Placing the wireless sensors in an open stairwell is an additional possibility to avoid one or more reinforced steel ceilings that are an obstacle For additional details regarding the antennas...

Страница 7: ...n batteries into fire Explosion hazard Do not subject batteries to mechanical stress and do not dismantle them as leaking battery fluid is highly corrosive and lithium can generate severe heat or can...

Страница 8: ...correctly SET key The battery counter is reset by pressing and holding the SET key 6 seconds 3 1 1 Transmitted frequency radio channel The frequency band setting is factory hard wired The set frequenc...

Страница 9: ...schedule Calibrate wireless sensor Replace batteries 5 4 2 Accessories Replacing battery Monitoring of the battery is based on an energy consumption count For this reason only the specific manufactur...

Страница 10: ...re The interruption of the radio connection is indicated by a red blinking light at an interval of 10 seconds Reestablishing the radio connection can take up to 1 minute Connection test Blinks green r...

Страница 11: ...en areas and with line of sight Signal weakening in air This example makes the dramatic relation between free space damping and transmission frequency very clear The damping factor for solid materials...

Страница 12: ...s good contact the lead ends should have between 8 5 9 5mm of the insulation stripped Ambient temperature 30 C 55 C non condensing Protective class IP30 external power supply UB 10 30VDC 24VDC up to 1...

Страница 13: ...1 Wireless Sensor RT2e 5 4 2 Accessories Part no Function 3454 US RT2e wireless sensor 2 x external temperature Part no Name 2760 US Aerial 915 MHz band FCC yellow Included in scope of delivery 31xx x...

Страница 14: ...14 EN Wireless Sensor RT2e EL6107E Technical data 5 5 Label Locations...

Страница 15: ...EN 15 Wireless Sensor RT2e EL6107E Technical data IT ES EN EN FR IT ES 5 6 Dimensional drawing...

Страница 16: ...04 EN 301 489 3 V1 4 1 2002 08 EMV Guideline 2004 108 EG EN 55022 2008 05 EN 50130 4 2003 09 EN 50371 2002 11 Low Voltage Directive 2006 95 EG EN 60650 1 2006 11 EN 61000 6 1 2007 10 EN 61000 6 3 2007...

Страница 17: ...ot be used for active transmissions but spurious emissions can be produced The levels are given in EIRP Electrical Field Strength Power at a distance of 3 meters White Paper 915MHz band Section 15 249...

Страница 18: ...diation Exposure Statement This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment This equipment should be installed and operated with minimum distance 20...

Страница 19: ...EN 19 Wireless Sensor RT2e EL6107E Approvals IT ES EN EN FR IT ES...

Страница 20: ...EN 20 Wireless Sensor RT2e EL6107E IT ES EN EN FR IT ES Revision History Author Date Version Description A Gubler 26 06 2012 First edition...

Страница 21: ...rror messages 10 ETSI 16 F FCC 17 I ID number 5 Initial startup 6 M Maintenance schedule 9 Measurement range 12 P Power supply 12 Precautionary measures 7 Protection class 12 PT100 8 PT100 2 3 lead 12...

Страница 22: ...Manual Wireless Sensor RT2e EL6107E 08 2012 Head Office ELPRO BUCHS AG Lang ulistrasse 62 CH 9470 Buchs SG Switzerland email swiss elpro com For local representatives see www elpro com www pdf datalo...

Отзывы: