background image

18 - EN

Wireless Sensor RT2e

EL6107E

A p p r o v a l s

FCC STATEMENT

This product has been tested and complies with the specifications for a Class B digital device, pursuant 
to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful 
interference in a residential installation. This equipment generates, uses, and can radiate radio frequency 
energy and, if not installed and used according to the instructions, may cause harmful interference to radio 
communications.
However, there is no guarantee that interference will not occur in a particular installation. If this equipment 
does cause harmful interference to radio or television reception, which is found by turning the equipment 
off and on, the user is encouraged to try to correct the interference by one or more of the following 
measures:

- Reorient or relocate the receiving antenna
- Increase the separation between the equipment and receiver
- Connect the equipment to an outlet other than the receiver's
- Consult a dealer or an experienced radio/TV technician for assistance

Radiation Exposure 
Statement

This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. 
This equipment should be installed and operated with minimum distance 20cm between the radiator and 
your body.

6.4

INDUSTRY CANADA

This Class B digital apparatus complies with Canadian ICES-003, RSS210.
The use of this device in a system operating either partially or completely outdoors may require the user 
to obtain a license for the system according to the Canadian regulations.

6.5

Conclusion

The data transfer between wireless dataloggers and radio sensors could be seen as a safe way to 
exchange data.
This conclusion is valid as long as the wireless datalogger system is secured against any kind of fraud 
from the inside or outside of the company. This security task has to be fulfilled by the company internal IT 
department or other related departments.

Further information

More information regarding rules and requirements are found at:
http://www.fcc.gov
ETSI standards are found at:
http://www.etsi.org
The CEPT/ERC rec 70-03 are found at:
http://www.ero.dk
The ARIB STD-T66 regulation is found at:
http://www.arib.or.jp/english/index.html
The Australian/New Zealand Standard AS/NZS 4268:2003 are found at:
http://www.standards.org.au

Содержание RT2e

Страница 1: ...Wireless Sensor RT2e EL6107E Wireless Sensor RT2e Operation Manual...

Страница 2: ...2 EN Wireless Sensor RT2e EL6107E...

Страница 3: ...sor RT2e 8 3 1 Initial startup 8 3 1 1 Transmitted frequency radio channel 8 3 2 Operation 9 3 3 Maintenance 9 4 Status and error messages 10 5 Technical data 11 5 1 Radio settings 11 5 2 Environment...

Страница 4: ...VED INCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION This product is subject to CE marking The manufacturer guarantees that this product complies with the relevant guidelines EN 61000 6 2 200...

Страница 5: ...internal batteries On the front side there is a status display green red LED and a type label which documents the wireless sensor designation and the ID number of the sensor 1 Aerial 2 Status display...

Страница 6: ...eption Placing the wireless sensors in an open stairwell is an additional possibility to avoid one or more reinforced steel ceilings that are an obstacle For additional details regarding the antennas...

Страница 7: ...n batteries into fire Explosion hazard Do not subject batteries to mechanical stress and do not dismantle them as leaking battery fluid is highly corrosive and lithium can generate severe heat or can...

Страница 8: ...correctly SET key The battery counter is reset by pressing and holding the SET key 6 seconds 3 1 1 Transmitted frequency radio channel The frequency band setting is factory hard wired The set frequenc...

Страница 9: ...schedule Calibrate wireless sensor Replace batteries 5 4 2 Accessories Replacing battery Monitoring of the battery is based on an energy consumption count For this reason only the specific manufactur...

Страница 10: ...re The interruption of the radio connection is indicated by a red blinking light at an interval of 10 seconds Reestablishing the radio connection can take up to 1 minute Connection test Blinks green r...

Страница 11: ...en areas and with line of sight Signal weakening in air This example makes the dramatic relation between free space damping and transmission frequency very clear The damping factor for solid materials...

Страница 12: ...s good contact the lead ends should have between 8 5 9 5mm of the insulation stripped Ambient temperature 30 C 55 C non condensing Protective class IP30 external power supply UB 10 30VDC 24VDC up to 1...

Страница 13: ...1 Wireless Sensor RT2e 5 4 2 Accessories Part no Function 3454 US RT2e wireless sensor 2 x external temperature Part no Name 2760 US Aerial 915 MHz band FCC yellow Included in scope of delivery 31xx x...

Страница 14: ...14 EN Wireless Sensor RT2e EL6107E Technical data 5 5 Label Locations...

Страница 15: ...EN 15 Wireless Sensor RT2e EL6107E Technical data IT ES EN EN FR IT ES 5 6 Dimensional drawing...

Страница 16: ...04 EN 301 489 3 V1 4 1 2002 08 EMV Guideline 2004 108 EG EN 55022 2008 05 EN 50130 4 2003 09 EN 50371 2002 11 Low Voltage Directive 2006 95 EG EN 60650 1 2006 11 EN 61000 6 1 2007 10 EN 61000 6 3 2007...

Страница 17: ...ot be used for active transmissions but spurious emissions can be produced The levels are given in EIRP Electrical Field Strength Power at a distance of 3 meters White Paper 915MHz band Section 15 249...

Страница 18: ...diation Exposure Statement This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment This equipment should be installed and operated with minimum distance 20...

Страница 19: ...EN 19 Wireless Sensor RT2e EL6107E Approvals IT ES EN EN FR IT ES...

Страница 20: ...EN 20 Wireless Sensor RT2e EL6107E IT ES EN EN FR IT ES Revision History Author Date Version Description A Gubler 26 06 2012 First edition...

Страница 21: ...rror messages 10 ETSI 16 F FCC 17 I ID number 5 Initial startup 6 M Maintenance schedule 9 Measurement range 12 P Power supply 12 Precautionary measures 7 Protection class 12 PT100 8 PT100 2 3 lead 12...

Страница 22: ...Manual Wireless Sensor RT2e EL6107E 08 2012 Head Office ELPRO BUCHS AG Lang ulistrasse 62 CH 9470 Buchs SG Switzerland email swiss elpro com For local representatives see www elpro com www pdf datalo...

Отзывы: