background image

EN - 9

Wireless Sensor RT2e
EL6107E

W i r e l e s s   S e n s o r   R T 2 e

IT

ES

EN

EN

FR

IT

ES

In the event of a poor test result, shifting the wireless sensor can lead to an improvement in the radio 
connection 

 2.1 

Antenna position

.

If no radio connection can be established, the channel settings should be checked. 

Radio channel
change

If the radio channel needs to be changed during operation, it is necessary to briefly press the SET key 
after selecting the new channel.

3.2

Operation

Undisrupted operation is indicated by a green, blinking light of the status indicator at intervals of 10 
seconds.

Status indicator

3.3

Maintenance

Maintenance 
schedule

To ensure proper functioning of the wireless sensor, the following steps should be part of a periodic 
maintenance schedule:

- Calibrate wireless sensor
- Replace batteries 

 5.4.2 

Accessories

Replacing battery

Monitoring of the battery is based on an energy consumption count. For this reason, only the specific 
manufacturer recommended battery should be used. Do not remove the battery from the wireless sensor 
when it is not in use. The use of third party batteries or removal of batteries will produce incorrect status 
information at the battery indicator.

Status display - test result

Quality of the radio connection

Blinks, number

Color

good radio connection

100%

5

green

80%

4

green

60%

3

green

40%

2

green

poor radio connection

20%

1

green

No radio connection or wrong settings*

1

red

Status indicator - Operation

Quality of the radio connection

Blinks, number

Color

good radio connection

1

green

No radio connection or wrong settings*

1

red

AFTER THE BATTERIES ARE CHANGED, THE SET KEY MUST BE PRESSED AND HELD 
FOR 6 SECONDS, OTHERWISE THE ENERGY COUNTER WILL NOT FUNCTION

Содержание RT2e

Страница 1: ...Wireless Sensor RT2e EL6107E Wireless Sensor RT2e Operation Manual...

Страница 2: ...2 EN Wireless Sensor RT2e EL6107E...

Страница 3: ...sor RT2e 8 3 1 Initial startup 8 3 1 1 Transmitted frequency radio channel 8 3 2 Operation 9 3 3 Maintenance 9 4 Status and error messages 10 5 Technical data 11 5 1 Radio settings 11 5 2 Environment...

Страница 4: ...VED INCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION This product is subject to CE marking The manufacturer guarantees that this product complies with the relevant guidelines EN 61000 6 2 200...

Страница 5: ...internal batteries On the front side there is a status display green red LED and a type label which documents the wireless sensor designation and the ID number of the sensor 1 Aerial 2 Status display...

Страница 6: ...eption Placing the wireless sensors in an open stairwell is an additional possibility to avoid one or more reinforced steel ceilings that are an obstacle For additional details regarding the antennas...

Страница 7: ...n batteries into fire Explosion hazard Do not subject batteries to mechanical stress and do not dismantle them as leaking battery fluid is highly corrosive and lithium can generate severe heat or can...

Страница 8: ...correctly SET key The battery counter is reset by pressing and holding the SET key 6 seconds 3 1 1 Transmitted frequency radio channel The frequency band setting is factory hard wired The set frequenc...

Страница 9: ...schedule Calibrate wireless sensor Replace batteries 5 4 2 Accessories Replacing battery Monitoring of the battery is based on an energy consumption count For this reason only the specific manufactur...

Страница 10: ...re The interruption of the radio connection is indicated by a red blinking light at an interval of 10 seconds Reestablishing the radio connection can take up to 1 minute Connection test Blinks green r...

Страница 11: ...en areas and with line of sight Signal weakening in air This example makes the dramatic relation between free space damping and transmission frequency very clear The damping factor for solid materials...

Страница 12: ...s good contact the lead ends should have between 8 5 9 5mm of the insulation stripped Ambient temperature 30 C 55 C non condensing Protective class IP30 external power supply UB 10 30VDC 24VDC up to 1...

Страница 13: ...1 Wireless Sensor RT2e 5 4 2 Accessories Part no Function 3454 US RT2e wireless sensor 2 x external temperature Part no Name 2760 US Aerial 915 MHz band FCC yellow Included in scope of delivery 31xx x...

Страница 14: ...14 EN Wireless Sensor RT2e EL6107E Technical data 5 5 Label Locations...

Страница 15: ...EN 15 Wireless Sensor RT2e EL6107E Technical data IT ES EN EN FR IT ES 5 6 Dimensional drawing...

Страница 16: ...04 EN 301 489 3 V1 4 1 2002 08 EMV Guideline 2004 108 EG EN 55022 2008 05 EN 50130 4 2003 09 EN 50371 2002 11 Low Voltage Directive 2006 95 EG EN 60650 1 2006 11 EN 61000 6 1 2007 10 EN 61000 6 3 2007...

Страница 17: ...ot be used for active transmissions but spurious emissions can be produced The levels are given in EIRP Electrical Field Strength Power at a distance of 3 meters White Paper 915MHz band Section 15 249...

Страница 18: ...diation Exposure Statement This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment This equipment should be installed and operated with minimum distance 20...

Страница 19: ...EN 19 Wireless Sensor RT2e EL6107E Approvals IT ES EN EN FR IT ES...

Страница 20: ...EN 20 Wireless Sensor RT2e EL6107E IT ES EN EN FR IT ES Revision History Author Date Version Description A Gubler 26 06 2012 First edition...

Страница 21: ...rror messages 10 ETSI 16 F FCC 17 I ID number 5 Initial startup 6 M Maintenance schedule 9 Measurement range 12 P Power supply 12 Precautionary measures 7 Protection class 12 PT100 8 PT100 2 3 lead 12...

Страница 22: ...Manual Wireless Sensor RT2e EL6107E 08 2012 Head Office ELPRO BUCHS AG Lang ulistrasse 62 CH 9470 Buchs SG Switzerland email swiss elpro com For local representatives see www elpro com www pdf datalo...

Отзывы: