PG4UW MC
153
text included in Log file will be truncated. When the option is unchecked, the size of Log file
is unlimited, respectively is limited by free disk space only.
option
Maximum Log file size
specifies the maximum size of Log file in kB
option
Amount of truncated text
specifies the percentage of Log file text, which will be
truncated after Maximum Log file size is reached. The higher value means more text will be
truncated (removed) from Log file.
Note: Lines start with '+' are shown in the log file, but not in the log at screen to keep better
overview of the on-screen log.
Common information:
Index of Programmer Site
is integer number from 1 to 8 which defines unambiguously each
running Programmer Site.
Serial number of Programmer Site
defines unambiguously the programmer or programmer
site used. Instance will search all programmers connected on USB Bus until it finds
programmer (site) with desired serial number. Programmers or Programmer Sites with different
serial numbers will be ignored. If the PG4UWMC does not find desired Programmer Site, the
Programmer Site will be set to Demo mode with status set to "Not found".
On one computer, 8 Programmer Sites can be run at the same time.
Panel Job Report
settings are used to set mode of using Job Report.
Job Report represents the summary description of operation recently made on device. Job is
associated with project file and it means the operation starting with Load project until loading of
new project or closing program PG4UWMC.
Job Report
contains following information:
project name
project date
Protected mode status
PG4UWMC software version
programmer type and serial number
start time of executing the Job (it means time when Load project operation was performed)
end time of executing the Job (time of creating the Job Report)
device name
device type
checksum
device operation options
serialization information
statistics information
Job Report is generated in following cases:
user command Load project is selected
closing or disconnecting programmer sites is selected
closing the PG4UW MC
device Count down counter reaches 0 (finished status)
manually by user, when menu "File / Job Report" is used
The Job Report is generated for recently loaded project file, only when statistics value of Total
is greater than 0.
It means, at least one device operation (program, verify...) must be performed.
Содержание BeeHive204
Страница 7: ...Introduction 7 Introduction ...
Страница 12: ...Elnec s r o 12 Quick Start ...
Страница 15: ...Detailed description 15 Detailed description ...
Страница 16: ...Elnec s r o 16 BeeHive204 ...
Страница 33: ...BeeProg2 BeeProg2C 33 BeeProg2 BeeProg2C ...
Страница 50: ...Elnec s r o 50 SmartProg2 ...
Страница 59: ...Setup 59 Setup ...
Страница 63: ...Setup 63 Step 7 Check your settings and then click on Install button Step 8 Installation process will start ...
Страница 66: ...Elnec s r o 66 PG4UW ...
Страница 141: ...PG4UWMC 141 PG4UWMC ...
Страница 162: ...Elnec s r o 162 Common notes ...
Страница 176: ...Elnec s r o 176 Troubleshooting and warranty ...