Technical Support Line +44 (0)23 9269 6638 (Option 3)
PAK200544 Iss 01A Mar 2012
©2012 ELMDENE INTERNATIONAL LTD
D
IAGNOSTICS
A green LED is provided for fault diagnosis. The Fault Diagnostic LED becomes active when the front cover
is opened. Temporarily select a 5 second sounder timeout or set Engineer mode to active to ensure fault
indication tracks changes in fault status.
Note: Commissioning Mode is only active when ENG is connected to 9V to 15Vdc.
Commissioning
Tones
Status Indicated
Action
Single Click
Tamper closing – front or rear
Use to ensure that the rear tamper has been
trimmed or extended to the correct length,
or that the cover has been fully closed.
Double Click
Tamper opening – front or rear
Use to verify correct operation of tamper
circuit
Continuous slow
clicks
Rear tamper not closed when
cover tamper is closed
Remove unit from wall and adjust rear
tamper until it closes when the unit is
correctly fitted.
Continuous fast
clicks
Battery not connected or faulty
when cover tamper is closed
Open cover and check that battery is
correctly connected.
NOTE: Diagnostic LED only activated when Cover is open
Diagnostic LED
Status Indicated
Action
Single Flash
Battery voltage low
Change battery (unless newly fitted and is
still charging)
2 Flashes
Battery test failed
Change battery
3 Flashes
Piezo self test failed
Change sounder
4 Flashes
Battery charger failure
Change sounder
8