Note 1.
Where the siren trigger is NOT pulled up to > +8.5V by the control panel when in standby mode, or
is operated via volt-free contacts, it will be necessary to fit a pull-up resistor (any value between 1k0
and 10k), as shown, at the control panel to enable monitoring of the Trigger connection.
Note 2.
If preferred, pull the ENG i/p high using a programmable control panel output, rather than wiring it
directly to H+.