Technical Support Line +44 (0)23 9269 6638 (Option 3)
PAK200544 Iss 01A Mar 2012
©2012 ELMDENE INTERNATIONAL LTD
C
OMMISSIONING
1)
Cut Comfort LED loop if Comfort LEDs are
NOT
required.
2)
Connect ENG i/p to a switched output of the control panel (set high), or to H+.
3)
Apply power to the sounder via H+ and H- from control panel.
4)
Connect the black battery lead to BT- (slide sleeve to expose conductor).
5)
Check that tamper signal is present at the control panel.
6)
Manually operate the rear tamper. As the rear tamper closes the piezo will emit a low level click.
As it opens the piezo will emit a double click. If the rear tamper extender is required, trim to
length as necessary with pliers or side cutters.
7)
Fix backplate securely to the wall using a minimum of 3 x No. 10 fixing screws suitable for the
material of the mounting surface. (See Fig. 4)
8)
Fit cover. As the front tamper closes the piezo will emit a low level click. As it opens the piezo will
emit a double click.
9)
When the cover is closed the unit will perform a self-test. This takes approximately 5 seconds. If
the battery is faulty the unit will indicate this with a series of fast clicks from the piezo. If the rear
tamper is not closed the unit will indicate this with a series of slow clicks.
10)
Remove cover. If connected, disconnect ENG from H+. If ENG is connected to control panel, set
output LOW. NOTE: Sounder will activate.
11)
Refit the cover.
12)
Test sounder by triggering R- input.
13)
Test strobe operation by triggering ST- input.
14)
If necessary, open the cover to fit timer link to select 15min sound -off time.
15)
Re-fit cover and secure using fixing screws.
16)
Disconnect H+ and check that the siren activates. Restore H+.
17)
Disconnect H- and check that the siren activates. Restore H-.
18)
At control panel, disconnect R-, check siren activates and reports a tamper to the control panel,
then reconnect R-
19)
Commissioning complete.
M
AINTENANCE
The Quartz-G3
sounder should be tested for correct operation on a periodic basis. A minimum of one
check every 12 months is recommended. The following features should be verified on each maintenance
visit:
1)
Correct operation of sounder and strobe from control panel signals
2)
Correct operation of cover and rear tampers.
3)
Remove the H+ supply from the control panel and check that the internal battery voltage as
measured between BT+ and BT- is greater than 6.0v dc. If the battery voltage is less than this
value replace the battery and re-connect observing CORRECT polarity.
4)
Check for signs of significant water or insect ingress. Clean as necessary.
SAB
B
ATTERY
R
EMOVAL
The SAB battery may be removed for disposal at end of product life or if it is detected faulty when tested
(see Maintenance above). To remove the battery, disconnect red and black leads from BT+ and BT- and
unclip battery from holder. To fit a new battery, clip into holder, route battery cables around clips and
reconnect positive (RED) lead to BT+ and negative (BLACK) lead to BT-.
IMPORTANT: Ensure correct polarity of connections and that exposed battery leads DO NOT accidentally
touch.
Dispose of used batteries in accordance with all national and local regulations
7