background image

Technical Support Line +44 (0)23 9269 6638 (Option 3) 

PAK200544 Iss 01A   Mar 2012 

©2012 ELMDENE INTERNATIONAL LTD 

 
 

I

NSTALLATION AND 

S

ET

-U

P

 

 

 

1. 

Select a suitable mounting position for the Quartz-G3

 

sounder. 

2. 

Drill holes as required for fixing the backplate to the wall and for cable entry to the rear of the unit. 

 

 

 

3. 

Fit tamper extender (if required), and trim to desired length: 

 
 

             

                           

 

 

4. 

Route cable from control panel through cable entry cowl. 

5. 

Fit backplate to wall using minimum of 3 x No. 10 fixing screws suitable for material of mounting 
surface. 

 

TAMPER 
EXTENDER 
PARKING

COVER SCREW

PARKING

LOOP CABLE

 UNDER CABLE

 CLAMP

 

 

Fig 4: Backplate Mounting Positions 

 

 

 

 

 

             

 

                

    6 

 

Содержание Quartz-1000-G3

Страница 1: ...ld off supply failure detection Battery and piezo test with fault output Selectable sound auto cut off timer 5s for test or 15 minutes Full SAB using internal battery Twin Comfort LEDs selectable on off alternate flash Audible Tamper to assist commissioning Ring Line Monitoring Engineer Mode for quiet installation and maintenance Polycarbonate cover and backplate Microprocessor controlled Elmdene ...

Страница 2: ...r is removed Every 24 hours the Quartz G3 performs a self test to check the integrity of its on board battery its battery charging circuit and its piezo transducers If an error condition is detected a fault signal is generated This is normally connected back to the control panel An on board diagnostic LED guides the maintenance engineer to the source s of the fault To assist with commissioning the...

Страница 3: ...ted hardware reset OPTIONS SELECTION Sound Cut off Timer The Quartz G3 sounder will automatically stop sounding after 15 minutes unless J9 is removed in which case the sound will cut off after 5 seconds Comfort LEDs A wire loop is provided at J5 position cutting this loop will disable the comfort LEDs CONNECTIONS Piezo 2 Connections to sounder module s BT Positive connection to battery BT Negative...

Страница 4: ...Technical Support Line 44 0 23 9269 6638 Option 3 PAK200544 Iss 01A Mar 2012 2012 ELMDENE INTERNATIONAL LTD Figure 1 Board Connections J9 J5 4 Piezo Piezo BATT BATT Fault Fault ENG H H TS TR R ST ...

Страница 5: ...when in standby mode or is operated via volt free contacts it will be necessary to fit a pull up resistor any value between 1k0 and 10k as shown at the control panel to enable monitoring of the Trigger connection Note 2 If preferred pull the ENG i p high using a programmable control panel output rather than wiring it directly to H Fig 3 Multiple Cascade Quartz G3 Tamper Connection CONTROL PANEL EN...

Страница 6: ...red for fixing the backplate to the wall and for cable entry to the rear of the unit 3 Fit tamper extender if required and trim to desired length 4 Route cable from control panel through cable entry cowl 5 Fit backplate to wall using minimum of 3 x No 10 fixing screws suitable for material of mounting surface TAMPER EXTENDER PARKING COVER SCREW PARKING LOOP CABLE UNDER CABLE CLAMP Fig 4 Backplate ...

Страница 7: ...n by triggering ST input 14 If necessary open the cover to fit timer link to select 15min sound off time 15 Re fit cover and secure using fixing screws 16 Disconnect H and check that the siren activates Restore H 17 Disconnect H and check that the siren activates Restore H 18 At control panel disconnect R check siren activates and reports a tamper to the control panel then reconnect R 19 Commissio...

Страница 8: ...ded to the correct length or that the cover has been fully closed Double Click Tamper opening front or rear Use to verify correct operation of tamper circuit Continuous slow clicks Rear tamper not closed when cover tamper is closed Remove unit from wall and adjust rear tamper until it closes when the unit is correctly fitted Continuous fast clicks Battery not connected or faulty when cover tamper ...

Страница 9: ...rigger signal R disconnected floating Ensure R pulled up to above 8 5V Fault output open Battery not connected Check battery connections to terminal block Battery faulty or voltage low Replace battery Piezo fault Return unit to manufacturer Battery charger faulty Clicking noise from sounder during commissioning See Commissioning Mode table DISPOSAL OF PRODUCT AT END OF LIFE This product falls with...

Страница 10: ... mA max Strobe Battery Type Ni MH Voltage 6 0V Capacity 320 mAH Strobe Flash Rate 1 Hz reduces to 1 2 Hz after 15 minutes Comfort LEDs Alternate flash 85 per minute Material 3mm Polycarbonate all parts Tamper Detection Cover and Rear Kinetic Protection IK08 COMPLIANCE This product meets the essential requirements of the following EU Directives EMC 2004 108 EC RoHS 2002 95 EC WEEE 2002 96 EC Batter...

Отзывы: