MP200 Installation Manual
31
NOTE: for Safety Instructions: see the bottom of page 2 in this manual!!!
CONTROL PANEL
- Supply voltage .......................................................... 230V~ 50Hz +10-15%
- Maximum
power consumption
at rated voltage ........... 500mA
- Control unit board power consumption at 12V- ......... 210mA (at ON with NC inputs at +) – MP200/64 board
- Control unit board power consumption at 12V- ......... 235mA (at ON with NC inputs at +) – MP200256 board
- CU board power consu 1KP200D keypad ... 250mA a 12V- +) – MP200/64 board
- CU board power consu 1KP200D keypad ... 275mA a 12V- +) – MP200/256 board
- Power consumption of the KP200D alone ................ 40mA (with network LED on – backlight off)
- Control unit operating voltage ................................... from 10V5 to 15V—
- PS28 power supply unit
consumption
(M.S-40-15) ..... 13.8V— (14.5V set during manufacturing)
- Max. current available from PS28 (Meanwel S-40-15) . 2.8A (1.4A max. current available from control unit)
- Max. ripple ............................................................100 mV with I = 2,8A
- Current available for ext. devices ............................. 315mA (vers. MP200/64 + 1 KP200) 24hr autonomy:17Ah
battery
290mA (vers. MP200/256 + 1 KP200) 24hr autonomy: 17Ah
battery
415mA (vers. MP200/64 OM + 1 KP200) 24hr autonomy:
24Ah battery
415mA (vers. MP200/256 OM + 1 KP200) 24hr autonomy:
24Ah battery
415mA (vers. MP200/64 OM+ 1 KP200) 24hr autonomy:
27Ah battery
415mA (vers. MP200/256 OM+ 1 KP200) 24hr autonomy:
27Ah battery
- Batteries for housing in metal case ........................... 12V - 17Ah metal case vers.MP200/64
,
MP200/256
12V- 24/27Ah metal case version MP200/64 OM, MP200/
256 OM
- Anti-tamper ............................................................... 1A - 24V—
- Operating temp. guaranteed by the manufacturer .... -10°C + 55°C
- Operating temp. certified by IMQ .............................. + 5°C + 40°C
- Performance level guaranteed .................................. I (NC lines positive); II (single/double balance lines)
- Max. length of serial line between control unit/periph. 500 metres* (cable sec. 2x0.75 to 2 x 0.22 x data)
- Min/max input time .................................................... from 00 sec. to 180 sec. per 10 sec. step
- Min/max output time .................................................. from 00 sec. to 180 sec. per 10 sec. step
- Robbery alarm time U9 relay .................................... 30sec, 1, 3, 4, 5, 6, 7, 8, 9 min.
- 24h alarm time U10 relay .......................................... 30sec, 1, 3, 4, 5, 6, 7, 8, 9 min.
- Max. current available from electrical output ............ 10 mA supplementary U1 – U8 exits
- Flat battery limit setting ............................................. 11.4V
- Protection level of control unit case ............................ IP30 - IK04
- MP200/64 - 256 standard case size ......................... 330 x 415 x 85 mm
- MP200/64 - 256 OM case size .................................. 445 x 325 x 145 mm
NOTE
: The following models are covered by
IMQ - SECURITY SYSTEMS
:
MP200/64-OM with a 17Ah battery; 24Ah; 27Ah (large case)
MP200/256-OM with a 17Ah battery; 24Ah; 27Ah (large case)
13.0 Technical Characteristics