MP200 Installation Manual
14
M6 TERMINAL BOARD
+
Positive sensor power supply
-
Negative sensor power supply
Z7
Zone 7: programmable input
Z8
Zone 8: programmable input
T/A
Tamper/self-protection input balanced positive via an R =15Kohm.
M7 TERMINAL BOARD
+
Positive sensor power supply
-
Negative sensor power supply
Z4
Zone 4: programmable input
Z5
Zone 5: programmable input
Z6
Zone 6: programmable input
M8 TERMINAL BOARD
+
Positive sensor power supply
-
Negative sensor power supply
Z1
Zone 1: programmable input
Z2
Zone 2: programmable input
Z3
Zone 3: programmable input
M9 TERMINAL BOARD
-
Reference negative
KEY
Electromechanical key input
Note: this dedicated input (not programmable) may be connected to an
electromechanical normally open push contact key. Each complete sequence:
open - closed - open of the key contact causes a total system status change
(of all sectors). If this input is not used, it may be left free and with no special
device.
M10 TERMINAL BOARD
-
Device power supply on serial tamper input will be
LA
serial data line
LB
serial data line
+
Device power supply on serial line
M11 TERMINAL BOARD
Support terminal board for service keypad (in parallel with BUS1 terminal
boards). To allow programming with a service keypad without disconnecting
peripherals already connected.
M 6
M 7
M 8
M 9
M10
M11
Содержание MP 200
Страница 19: ......