Temperature regulation
menu is designed for setting controls over
heating equipment.
Touching
Temperature regulation
(fig. 116)
shows the names of the
individual heating circuits and icons
(fig. 117)
:
Saving mode
– preset temperature in the range 10 … 40°C.
Normal mode
– preset temperature in the range 10 … 40°C.
Party mode
– preset temperature in the range 10 … 40°C.
Anti-freeze mode
– is designed to maintain the minimum required
temperature in a range of 5 ... 15 °C.
AUTO
Heating program
– used to set the heating function and tempe-
rature for a week in a range of -20 … 50 °C.
Holiday mode
– is used for temporary interruption of the heating
program or other heating mode. During
Holiday mode
the
Saving
mode
is activate.
Touching on one of the mode icons activates the selected mode
for the assigned room (heating circuit). After activating the applied
settings change with the subsequent heating program or holiday
mode.
The required temperature may be set manually on the RFTC-10/G
unit. This adjustment is valid until the subsequent change of the
heating programme in RF Touch.
circuits). The amended scheme in every single room is active until
the next change in the set temperature of the plan. (Ie. if it is set to
change in a room at 15.00 h in a bedroom in 20.00 h, it returns to
the original temperature schedule in the room at 15.00 h but in the
bedroom at 20.00 h).
If you want to return collectively to the originally setting of the
heating programs, Set
Heating Program
AUTO
in the default screen −
The change is manifested in all rooms.
Main menu / Temperature regulation
fig. 115
fig. 116
fig. 117
The precedence of the heating modes
Holiday mode
Heating program
Saving Normal Party mode
Anti-freeze mode
AUTO
21. 3. 2010
Sunday
Main menu
Temperature regulation
Temperature regulation
Quick control
Detectors
Blinds
Dimming
Switching
room heating
bedroom heating
kitchen heating