Remote Control Options

The M1Cloud is a remote services application that leverages the power of the Internet and third party service 

providers.  It enables greater ease of access to the M1 for remote services and control, without the need for any 

cumbersome setup or configuration of the customer’s local area network such as port forwarding or Dynamic DNS 

(DDNS).  Elk’s third party service providers are essentially Elk Partners that have developed powerful server software 

to manage and coordinate the remote access.  

Through the remote service provider and the M1Cloud you can monitor M1 system status, remotely arm and disarm, 

and manage users by adding, changing, or removing them.  In addition, you can control automation features and 

receive email or text alerts whenever any particular event occurs.  These alerts may contain extended information 

such as the zone that caused an alarm, the user that disarmed, and the current temperature of a sensor.  Learn more 

at www.elkproducts.com/m1cloud

M1Cloud

Remote control apps for the iOS and Android platforms are available from third-party partners.  These apps provide 

varying levels of remote control capabilities for M1 controls.  Apps are purchased from the third-party developer 

through the App store or Google Play at nominal cost with no monthy fees required.  For more details on these apps, 

please visit www.elkproducts.com/m1-remote-control. 

Apps for iPhone, iPad, and Android Devices

M1ToGo Software for WIndows

M1ToGo is a 

free 

software application that provides users computer-based, internet remote access to their M1 from 

anywhere in the world. The secured Windows®-based platform allows users full access to their security system along 

with lighting and energy management, door/gate access and many other systems connected and controlled through 

the M1. For more details on M1ToGo, please visit www.elkproducts.com/m1togo.

Содержание ELK-M1XEP

Страница 1: ...ELK M1XEP M1 Ethernet Interface INSTALLATION MANUAL 828 397 4200 Voice 828 397 4415 Fax http www elkproducts com email info elkproducts com PO Box 100 Hwy 70W Hildebran NC 28637 USA L524 5 19 v2...

Страница 2: ...Java based web server user interface from the Version 2 firmware For details on email enhancements see page 9 For information on remote control options see page 16 Features and Specifications 3 Basics...

Страница 3: ...wer source A 2 1 mm barrel type connector is required for the power connection and the center of the barrel connector must be positive Any required network equipment i e Ethernet switch router cable m...

Страница 4: ...rk Router M1XEP PC Technical support from Elk Products Inc is limited to the setup and connection of the M1 Ethernet Interface inside the local network Connection to outside the local network may requ...

Страница 5: ...to link up with the Ethernet network 4 Enroll the M1 Ethernet Interface into the Control Using the keypad access the Installation Programming menu Menu 9 Choose Bus Module Enrollment Menu 1 and press...

Страница 6: ...the orange light will be on for 30 45 seconds When the reboot is complete both lights will be off for a second and then the orange light will come on solid and the green light will begin to blink Wai...

Страница 7: ...ead this information b When you are ready to proceed click the Find button This will open the Find M1XEPs screen c ElkRP willsearchforallM1EthernetInterfacesconnectedtothelocalnetwork Iftheinstallatio...

Страница 8: ...t to the M1 control through the M1XEP Many of the features provided by the M1XEP require newer versions of M1 Control firmware M1XEP firmware and ElkRP software Current software and firmware updates a...

Страница 9: ...ress of 192 168 0 251 3 Some third party devices use a TCP or non secure port for standard unencrypted communications on the local network If this port is needed select Enable Non Secure Port and ente...

Страница 10: ...ion with the M1XEP cannot be re established until the reboot process is complete Click Save Account under the File menu to save the changes to the database Sending Changes to the M1 Ethernet Interface...

Страница 11: ...n is where the email addresses and messages for email notification are entered Up to 16 addresses and messages can be stored Email addresses can be up to 48 characters long The message body may be up...

Страница 12: ...lick OK 2 On the telephone number screen enter a name and set the reporting format to 6 IP Dialing attempts should be set to 1 to enable reporting 3 In the Report the following to this number box chec...

Страница 13: ...tion specific to OH2000E receivers The Account Number must be a decimal value not hexadecimal between 0001 and 9999 Line and Receiver numbers may also be entered on this screen This information is obt...

Страница 14: ...et For additional fees each provider has extras such as letting you select a fully custom URL email services etc The free service allows you to select a URL in one of their sub domains For example Dyn...

Страница 15: ...s while doing this 1 Choose only a Stratum 2 server They are intended for public use Stratum 1 servers are reserved for use by governments large institutions and stratum 2 servers Synchronizing to a s...

Страница 16: ...Protocol 2601 Encrypted communications port Route outside to connect with ElkRP TCP Configurable by installer via Internet WAN 2601 is the default 21 M1XEP Firmware Updates Route outside if ElkRP wil...

Страница 17: ...wo data entry blocks labeled System URL IP and Port Manually enter the IP address or URL for the entire local network The router must be programmed to allow outside traffic through a specific port For...

Страница 18: ...method for forcing the M1XEP from a static IP address to DHCP mode or vice versa This is accomplished with the use of Jumper JP2 located beside the metal housing of the RJ45 connector 1 Power down th...

Страница 19: ...ates that the download is complete wait for the update to finish programming into the M1XEP The green light will stop flashing when the programming has almost finished Programming is complete when the...

Страница 20: ...y contain extended information such as the zone that caused an alarm the user that disarmed and the current temperature of a sensor Learn more at www elkproducts com m1cloud M1Cloud Remote control app...

Страница 21: ...ent or non changing IP address that is assigned to a node in a TCP IP network Static IP addresses are generally used for servers routers etc Dynamic IP Address an IP address that is automatically assi...

Страница 22: ...ted If the M1XEP does not appear on the find screen refer to the troubleshooting steps above The M1XEP and the computer must have IP addresses within the same subnet Check the IP address of the comput...

Страница 23: ...on did not receive report shown above If enabled verify Central Station is receiving the heartbeat supervision signal PROBLEM Central Station did not receive report POSSIBLE SOLUTIONS Verify Telephone...

Страница 24: ...www elkproducts com...

Отзывы: