4.1 - ELECTRICAL CONNECTIONS

Important! Switch off the device before working on the electrical connections.

The instrument is equipped with screw terminal boards for connection of electrical cables with a diameter of 2.5 mm2 (one conductor 
only per terminal for power connections). Make sure that power supply is the correct voltage for the device. TTL serial port cables and 
RS-485 serial port cables must be kept separate from the power cables.
The RS-485 network must be appropriately terminated, i.e. by inserting a 120 Ohm terminal resistor between the - and + terminals of 
the interface module.

4.2 - DISCLAIMER

This document is the exclusive property of ELIWELL CONTROLS SRL and may not be reproduced or circulated unless expressly authorized 
by  ELIWELL  CONTROLS  SRL  itself. The  same  applies  to  any  person  or  company  involved  in  preparing  and  editing  this  document. 
ELIWELL CONTROLS SRL reserves the right to amend or improve this document at any time without notice.

4.3 - RESPONSIbILITY AND RESIDUAL RISkS

ELIWELL CONTROLS SRL shall not be liable for damage resulting from:
  - Installation/uses other than those specified and, in particular, which do not comply with the safety requirements set out in the
    regulations and/or stated herein.
  - Use on panels that do not provide adequate protection against electric shock, water or dust when assembled.
  - Use on panels that allow access to dangerous parts without having to use tools.
  - Tampering and/or modification of the product.
  - Installation/use on panels that do not comply with applicable standards and regulations.

4.4 - CONDITIONS OF USE

PERMITTED USE

For safety reasons, the device must be installed and used according to the instructions provided. In particular, parts carrying dangerous 
voltages must not be accessible in normal conditions. The device must be adequately protected from water and dust according to the 
application, and must also be accessible only using tools (with the exception of the front panel).
Class 4 classification ISA SP100.11 (do not use for safety devices)

USES NOT PERMITTED

The device must not be used for applications other than those described.
Note that the relay contacts provided are of a functional type and therefore subject to malfunction: Any protection devices required by 
product standards, or suggested by common sense, must be installed externally to the instrument for obvious safety reasons.

9MAX0010-1 • Radio

Adapter

 • EN • 04/11

© Copyright Eliwell Controls s.r.l. 2011 All rights reserved

4 - wARNINGS

Содержание RadioAdapter

Страница 1: ...RadioAdapter MANAGEMENT AND MONITORING ISM 2 4 GHz wireless system for plant monitoring and control USER MANUAL...

Страница 2: ...2 2 3 Saving settings 7 2 3 How to install a repeater 8 2 3 1 Initializing a repeater 8 2 3 2 Self configuring a repeater 8 2 3 3 Saving repeater settings 8 2 4 Configuring the PAN C 9 2 4 1 Transferr...

Страница 3: ...against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordanc...

Страница 4: ...1 5 Installing the antenna NO FCC models The antenna can be inserted straight into the RadioAdapter connector or panel mounted and connected to RadioAdapter using the cable supplied in the Antenna ki...

Страница 5: ...e 19200 bps parity odd stop bit 1 CCA0B0T01M500 RadioKey Modbus bit rate 19200 bps parity none stop bit 1 NOTE The features described in this table depend on the value of the 11th digit of the RadioKe...

Страница 6: ...is now configured as PAN C and all PAN C information is sent to the RadioKey From now on the RadioKey can only be used with this network We recommend you mark this RadioAdapter with the sticker suppli...

Страница 7: ...gs Power Supply Power Supply Power Supply TTL RS485 Configure the Televis or Modbus address of the devices to be connected to the NODE Connect the devices to the NODE via TTL or RS 485 Switch on the d...

Страница 8: ...TER The GREEN LED on the repeater will now start to blink fast 2 3 2 Self configuring a repeater 2 3 3 Saving repeater settings Power Supply Power Supply Disconnect the RadioKey from the repeater Wait...

Страница 9: ...NOTA Communication between NODES repeaters and PAN C and the monitoring device will commence after at least 1 minute has passed after each component of the network was switched on 2 5 Changes to netwo...

Страница 10: ...NODE Place a new RadioAdapter in the place of the NODE you removed Install and configure the new NODE following the steps outlined in section How to install a NODE Repeat the PAN C configuration as de...

Страница 11: ...on Saving repeater settings Power Supply Power Supply 1 2 3 5 2 Setting communication channel manually Power Supply Power Supply Power Supply PAN C PAN C NODE Power Supply NODE 1 2 3 4 OTHER NODES 1 S...

Страница 12: ...ithout notice 4 3 RESPONSIBILITY AND RESIDUAL RISKS ELIWELL CONTROLS SRL shall not be liable for damage resulting from Installation uses other than those specified and in particular which do not compl...

Отзывы: