H1_Glue amount test
Step 1: Construct new program Cpk_H1_Point, check valve glue output
1.
Right mouse key
2.
Open New/Old working file
3.
Construct testing point glue amount program
4.
Provide glue pressure function button(No action for valve, used to adjust valve
pressure)
5.
Start valve on(glue pressure on Valve on action
作
)
6.
Single action dispense button(Single action on/off + glue pressure single
action on/off valve action)
7.
Continue glue output button(Continue on glue pressure Continue on/off
valve action)
8.
Left/Right valve switch
9.
Set seconds(1000ms as 1 sec.) for single action glue output according to this column
(Continue glue output,
cannot stop glue)
Adjust glue action procedure: Inside system needle height and center point cabrilation done, use needle and test that valve glue
output is smooth, See Pic. 1
If glue output isn’t smooth:1.Check whether hardwares are working properly 2.Check whether there is bubbles in glue tube