H2(Spray valve)Valve calibration:M9_Z axis base height:touch auto
searching surface
When to use :Working dispense Z height has an offset, renew needle and each axis hardware. Specifies to
valve calibration way
1.
Select M9_Z axis base height :touch auto searching surface
2.
Move X.Y.Z axis, align nut lead angle with height detection PIN as right Pic.1
3.
Manually move needle until
touches light off like Pic. 4.1,
move up so that light is on as Pic. 4.2
4.
Light On position is mZ31835um, move up 3000um= parameter is mZ28835um
5.
Revise coordinate
5
1
4