ELIS PLZEŇ a. s.
Project design, installation and service manual
Page 66 of 72
Electromagnetic flowmeter FLONET FH30xx
ELIS PLZE
Ň a. s., Luční 425/15, 301 00 Plzeň, Czech Republic, phone.: +420 377 517 711, fax: +420 377 517 722
Es 90678K
Ordinal numbers of the order number digits
26 27 28 29 30 31 32
ORDER NUMBER
Number of
samples to be
averaged
25
1
50
2
100
3
150
4
200
5
250
6
Non-standard
x
Measurement
insensitivity
Standard ±0
.5% Q
3
1
Non-standard
x
Language
Česky
0 1
English
0 2
Dutch
0 3
Español
0 4
Polski
0 5
Français
0 6
Italiano
0 7
Deutsch
0 8
По Русски
0 9
Português
1 0
Data on display
Aggregate volume
1
Time / date
2
Operating time
3
Excitation current
4
Flow rate in per cent
5
Last error
6
Flow rate 100%
(l/s)
Flow rate for Q
3
(Q
3
= Q for v = 8 m/s)
1
Order-specified flow rate
x
Current output
Not requested
1
−
Q
…
+Q (Q = Q
3
, Q
3
= Q for v = 8 m/s)
2
−
Q
…
+Q according to order
3
0 … |Q|
(Q = Q
3
, Q
3
= Q for v = 8 m/s)
4
0 … |Q|
according to order
5
Fixed current 4 to 20mA (0 to Q
3
, Q
3
= Q for v = 8 m/s)
6
Fixed current 4 to 20mA according to order
7